Product Datasheet Search Results:

BVP:275729.pdf296 Pages, 14056 KB, Original

Product Details Search Results:

Siemens.com/BVP:275721
LXA0861-LR-X* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 439...
2419 Bytes - 06:25:32, 16 November 2024
Siemens.com/BVP:275722
LXA0861-LL-X* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 439...
2419 Bytes - 06:25:32, 16 November 2024
Siemens.com/BVP:275723
LXA0861-LR-Y* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 439...
2420 Bytes - 06:25:32, 16 November 2024
Siemens.com/BVP:275724
LXA0861-LL-Y* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 439...
2420 Bytes - 06:25:32, 16 November 2024
Siemens.com/BVP:275725
LXA0861-LV-X* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 800...
2420 Bytes - 06:25:32, 16 November 2024
Siemens.com/BVP:275727
LXA0861-LV-Y* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 1\u...
2427 Bytes - 06:25:32, 16 November 2024
Siemens.com/BVP:275728
LXA0861-LH-Y* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 3\u00a0200\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0892\u00a0mm\u00b2 Mechanical Design Height 1\u...
2427 Bytes - 06:25:32, 16 November 2024

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
1SDX275729R1.pdf0.551Request