Did you mean: BVP:077160
Product Datasheet Search Results:
- BVP:077166
- Siemens
- LDC6615-LHL
Product Details Search Results:
Siemens.com/BVP:077160
LDC6615-2.4 Standard length 2.4 m Model Product designation trunking unit for LD busbar trunking system Product type designation LDC6615-2,4 General technical data Configuration of the busbars L1,L2,L3,N,L3,L2,L1,PE Voltage Insulation voltage at AC / rated value 1\u00a0000\u00a0V at DC / rated value 1\u00a0200\u00a0V Protection class Protection class IP IP54 Electricity Number of circuits / in a trunking unit 1 Short-time current resistance (Icw) / at 690 V limited to 0.1 s / rated value 130\u00a0kA limited...
4730 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077161
LDC6615-3.2 Standard length 3.2 m Model Product designation trunking unit for LD busbar trunking system Product type designation LDC6615-3,2 General technical data Configuration of the busbars L1,L2,L3,N,L3,L2,L1,PE Voltage Insulation voltage at AC / rated value 1\u00a0000\u00a0V at DC / rated value 1\u00a0200\u00a0V Protection class Protection class IP IP54 Electricity Number of circuits / in a trunking unit 1 Short-time current resistance (Icw) / at 690 V limited to 0.1 s / rated value 130\u00a0kA limited...
4730 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077162
LDC6615-D Expansion compensation Model Product designation trunking unit for LD busbar trunking system Product type designation LDC6615-D General technical data Configuration of the busbars L1,L2,L3,N,L3,L2,L1,PE Voltage Insulation voltage at AC / rated value 1\u00a0000\u00a0V at DC / rated value 1\u00a0200\u00a0V Operating voltage / at AC at 50 Hz / rated value / maximum 1\u00a0000\u00a0V at 60 Hz / rated value / maximum 1\u00a0000\u00a0V Protection class Protection class IP IP54 Current Number of circuits...
4776 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077163
LDC6615-V-2.4 Vertical length 2.4 m Model Product designation trunking unit for LD busbar trunking system Product type designation LDC6615-V-2,4 General technical data Configuration of the busbars L1,L2,L3,N,L3,L2,L1,PE Voltage Insulation voltage at AC / rated value 1\u00a0000\u00a0V at DC / rated value 1\u00a0200\u00a0V Protection class Protection class IP IP54 Electricity Number of circuits / in a trunking unit 1 Short-time current resistance (Icw) / at 690 V limited to 0.1 s / rated value 130\u00a0kA lim...
4734 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077164
LDC6615-V-3.2 Vertical length 3.2 m Model Product designation trunking unit for LD busbar trunking system Product type designation LDC6615-V-3,2 General technical data Configuration of the busbars L1,L2,L3,N,L3,L2,L1,PE Voltage Insulation voltage at AC / rated value 1\u00a0000\u00a0V at DC / rated value 1\u00a0200\u00a0V Protection class Protection class IP IP54 Electricity Number of circuits / in a trunking unit 1 Short-time current resistance (Icw) / at 690 V limited to 0.1 s / rated value 130\u00a0kA lim...
4734 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077165
LDC6615-LH Knee raised at both ends 0.5 m Model Product designation L unit (junction unit) for LD busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 16.7\u00a0Hz maximum 60\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 1\u00a0000\u00a0V at 60 Hz / rated value / maximum 1\u00a0000\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / for horizontal busbar box with flat busbars / rated value / maximum 2\u00a0000\u0...
3251 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077167
LDC6615-LHR Knee offset at both ends 0.5 m Model Product designation L unit (junction unit) for LD busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 16.7\u00a0Hz maximum 60\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 1\u00a0000\u00a0V at 60 Hz / rated value / maximum 1\u00a0000\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / for horizontal busbar box with flat busbars / rated value / maximum 2\u00a0000\u...
3251 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077168
LDC6615-LL Bracket flat at both ends 0.5 m Model Product designation L unit (junction unit) for LD busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 16.7\u00a0Hz maximum 60\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 1\u00a0000\u00a0V at 60 Hz / rated value / maximum 1\u00a0000\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / for horizontal busbar box with flat busbars / rated value / maximum 2\u00a0000\u...
3252 Bytes - 09:10:48, 27 November 2024
Siemens.com/BVP:077169
LDC6615-LLH Bracket offset at both ends 0.5 m Model Product designation L unit (junction unit) for LD busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 16.7\u00a0Hz maximum 60\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 1\u00a0000\u00a0V at 60 Hz / rated value / maximum 1\u00a0000\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / for horizontal busbar box with flat busbars / rated value / maximum 2\u00a000...
3256 Bytes - 09:10:48, 27 November 2024