2900 2900 Ctest1) 230 V F 200 200 200 200 200 Ctest1) 110 V F 800 800 800 800 800 Param. for R(I)1) k 0.700 0.710 0.757 0.814 0.879 Param. for R(I)1) n 1.30 1.30 1.30 1.32 1.32 Ordering code B57235S0479M000 B57235S0509M000 B57235S0609M000 B57235S0809M000 B57235S0100M000 1) For details on the capacitance Ctest as well as on the parameters k and n refer to "Application notes", chapters 1.6 and 1.7. Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 15 Inrush current limiters B57235 ICLs S235 Reliability data Test Standard Storage in dry heat IEC 60068-2-2 Storage in damp heat, steady state Rapid temperature cycling Endurance Cyclic endurance Transient load Test conditions Storage at upper category temperature T: 170 C t: 1000 h IEC Temperature of air: 40 C 60068-2-78 Relative humidity of air: 93% Duration: 21 days IEC Lower test temperature: 55 C 60068-2-14 Upper test temperature: 170 C Number of cycles: 10 I = Imax t: 1000 h I = Imax, 1000 cycles On-time
R/T charA acteristic B25/100 5,0 4,2 1202 2800 200 800 0,710 - 1,30 B57235S0509M000 6,0 4,0 1202 2800 200 800 0,757 - 1,30 B57235S0609M000 R 25 K Ordering code 8,0 3,5 1203 2900 200 800 0,814 - 1,32 B57235S0809M000 10,0 3,0 1203 2900 200 800 0,879 - 1,32 B57235S0100M000 1) For details on the capacitance CT as well as on the parameters k and n refer to "Application Notes", pages 40 - 42. 130 05/02 Inrush Current Limiters B57235 S 235 Reliability data Test Standard Test conditions R 25/R25 (typical) Remarks Storage in dry heat IEC 60068-2-2 Storage at upper category temperature T: 170 C t: 1000 h < 10 % No visible damage Storage in damp heat, steady state IEC 60068-2-3 Temperature of air: 40 C Relative humidity of air: 93 % Duration: 21 days <5% No visible damage Rapid temperature cycling IEC 60068-2-14 Lower test temperature: - 55 C < 10 % Upper test temperature: 170 C Number of cycles: 10 No visible damage Endurance I = Imax t: 1000 h < 10 % No visible damage Cyclic endurance I = Imax, 1000 cycl
: 55/170/21 * UL-Zulassung (E69802) * Optionen: Auch gegurtet lieferbar S153 4.7 10 15 33 20% 3.0 2.0 1.8 1.3 B57153S0479M000 B57153S0100M000 B57153S0150M000 B57153S0330M000 S235 5 6 8 10 20% 4.2 4.0 3.5 3.0 B57235S0509M000 B57235S0609M000 B57235S0809M000 B57235S0100M000 S236 2.5 5.0 10 12 16 20 25 50 80 20% 5.5 4.5 3.5 3.2 2.9 2.8 2.5 1.9 1.6 B57236S0259M000 B57236S0509M000 B57236S0100M000 B57236S0120M000 B57236S0160M000 B57236S0200M000 B57236S0250M000 B57236S0500M000 B57236S0800M000 13 max. 6 max. 36 _ 1 o0.6 5 TNT0410-3 6 max. 14 max. o9.5 max. 36 _ 1 o0.6 5 * Coated thermistor disk * Kinked leads of tinned copper wire * Useable in series connections up to 265 Vrms * Climatic category (IEC 60068-1): 55/170/21 * UL approval (E69802) * Options: Also available on tape TNT0411-B 6 max. 16 max. o11.5 max. 5 36 _ 1 o0.6 *) TNT0412-J *) 0.8 bei/for B57236S****L002 14 Isolationsspannung 1000 VDC fur 1 s \ Insulation voltage 1000 VDC for 1 s 2.5 3.0 5.0 8.0 15% 5.5 5.0 4.5 3.7 B57236S0259L002 B57236S03
1202 1203 1203 B25/100 K 2800 2800 2900 2900 Ctest1) 230 V F 200 200 200 200 Ctest1) 110 V F 800 800 800 800 Param. for R(I)1) k 0.710 0.757 0.814 0.879 Param. for R(I)1) n 1.30 1.30 1.32 1.32 Ordering code B57235S0509M000 B57235S0609M000 B57235S0809M000 B57235S0100M000 1) For details on the capacitance Ctest as well as on the parameters k and n refer to "Application Notes", chapters 2.6 and 2.7. Please read Important notes and Cautions and warnings at the end of this document. Page 2 of 6 Inrush current limiters B57235 ICLs S235 Reliability data Test Standard Storage in dry heat IEC 60068-2-2 Storage in damp heat, steady state Rapid temperature cycling Endurance Cyclic endurance Transient load Test conditions Storage at upper category temperature T: 170 C t: 1000 h IEC Temperature of air: 40 C 60068-2-78 Relative humidity of air: 93% Duration: 21 days IEC Lower test temperature: 55 C 60068-2-14 Upper test temperature: 170 C Number of cycles: 10 I = Imax t: 1000 h I = Imax, 1000 cycles On-time =