858AN00145A
Industrial Valves - KBFDG4V-3-5C07N-Z-M1-PC7 -H7-12

From Vickers

FeatureCodeDescription
VALVE TYPEKBF(KBF) PROPORTIONAL VALVE WITH INTEGRAL AMPLIFIER & FEEDBACK ARRANGMENT
CONTROL TYPED(D) DIRECTIONAL VALVE
MOUNTINGG(G) SUB PLATE MOUNTED
OPERATION4(4) SOLENOID OPERATED
PRESSURE RATINGV(V) MAX PRESSURE 350 BAR ON P,A & B PORTS
INTERFACE-3(3) ISO-4401 SIZE 03
SPOOL TYPE-5(5) P,A,B,T BLOCKED (ZERO LAP - BIASED CLOSED)
SPRING ARRANGEMENTC(C) SPRING CENTERED, DUAL SOLENOID
RATED FLOW07N(07N) 7 L/MIN (1.8 USGPM) WITH METER IN & METER OUT
MANUAL OVERRIDE-Z(Z) NO OVERRIDES
INPUT SIGNAL-M1(M1) +/- 10V VOLTAGE DEMAND SIGNAL, +/- 10V VOLTAGE MONITOR
ELECTRICAL CONNECTOR-PC7(PC7) 7 PIN CONNECTOR WITHOUT PLUG, NO ENABLE
COIL VOLTAGE-H(H) 24V DC
TANK PORT RATING7(7) T-PORT PRESSURE RATING 210 BAR
DESIGN CODE-12(12) DESIGN NUMBER
SPECIAL FEATURE_(0) OMIT FOR STANDARD