823AN00078K Industrial Valves - KBDG5V-7-33C130N65-EX-M1 -PE7-H1-10
From Vickers
Feature | Code | Description |
---|---|---|
VALVE TYPE | KB | (KB) PROPORTIONAL VALVE WITH INTEGRAL AMPLIFIER |
CONTROL TYPE | D | (D) DIRECTIONAL VALVE |
MOUNTING | G | (G) SUBPLATE MOUNTED |
OPERATION | 5 | (5) SOLENOID CONTROLLED / PILOT OPERATED |
PRESSURE RATING | V | (V) MAX PRESSURE 350 BAR FOR SIZE 7,8,10 & 315 BAR FOR SIZE 5 |
INTERFACE | -7 | (7) NFPA D07, CETOP 7 |
SPOOL TYPE | -33 | (33) BLEED A & B TO T WHEN SPOOL CENTERED |
SPRING ARRANGEMENT | C | (C) SPRING CENTERED, DUAL SOLENOID |
RATED FLOW | 130N65 | (130N65) 130 LPM (34.6 USGPM) A & 65 LPM (17.3 USGPM) B PORT FLOW |
PILOT SUPPLY | -EX | (EX) EXTERNAL PILOT SUPPLY WITH INTEGRAL, FIXED PILOT PRESSURE REDUCER |
PILOT DRAIN | _ | (0) EXTERNAL PILOT DRAIN |
MANUAL OVERRIDE | _ | (0) PLAIN OVERRIDES |
LVDT PLUG | -M1 | (M1) ?10V VOLT CONTROL SIGNAL |
ELECTRICAL CONNECTOR | -PE7 | (PE7) 7 PIN ELECTRICAL PLUG WITH PLUG |
COIL VOLTAGE | -H | (H) 24V DC AMPLIFIER SUPPLY |
TANK PORT RATING | 1 | (1) 8 BAR PILOT TANK PRESSURE MAXIMUM |
DESIGN CODE | -10 | (10) FOR 5,7 & 8 INTERFACE |