Product type designation | RF280R reader |
| SIMATIC RF200 Reader RF280R RS422 interface (3964R) IP67, -10 to +60 °C, 160x 80x 41 mm with integrated antenna |
Suitability for operation | ISO 15693 Transponder (MDS Dxxx), for connecting to communication modules |
Wireless frequencies |
Operating frequency / Rated value | 13.56 MHz |
Range / maximum | 200 mm; Range depends on transponder: Note http://support.automation.siemens.com/WW/view/en/67384965 |
Protocol / with radio transmission | ISO 15693, ISO 18000-3 |
Transfer rate / with radio transmission / maximum | 26.5 kbit/s |
Product feature / multitag-capable | No |
Electrical data |
Transfer rate / at the point-to-point connection / serial / maximum | 115.2 kbit/s |
Transmission time / for user data | |
for write access / per byte / typical | 0.6 ms |
for read access / per byte / typical | 0.6 ms |
Interfaces |
Standard for interfaces / for communication | RS422 |
Type of electrical connection | M12, 8-pin |
for communications interface | M12, 8-pin |
Mechanical data |
Material | PA 12 |
Color | Ti gray |
Tightening torque / of the screw for securing the equipment / maximum | 1.5 N·m |
Mounting distance / relating to metal surfaces / recommended / minimum | 0 mm |
Supply voltage, current consumption, power loss |
Supply voltage | |
at DC / Rated value | 24 V |
at DC | 20.4 ... 28.8 V |
Consumed current / at DC / at 24 V | |
typical | 0.13 A |
Permitted ambient conditions |
Ambient temperature | |
during operation | -25 ... +70 °C |
during storage | -40 ... +85 °C |
during transport | -40 ... +85 °C |
Protection class IP | IP67 |
Shock resistance | EN 60721-3-7 Class 7 M2 |
Shock acceleration | 500 m/s² |
Vibrational acceleration | 200 m/s² |
Design, dimensions and weight |
Width | 80 mm |
Height | 41 mm |
Depth | 160 mm |
Net weight | 0.6 kg |
Mounting type | 4 x M5 screws |
Wire length | |
for RS 422 interface / maximum | 1000 m |
Product properties, functions, components / general |
Display version | 3-color LED |
Product feature / silicon-free | Yes |
Standards, specifications, approvals |
Certificate of suitability | Radio according to R&TTE guidelines EN300 330 and EN 301489, FCC, cULus |
MTBF | 173 y |