Product type designation | CP 343-1 |
| Communications processor CP 343-1 for connection of SIMATIC S7-300 to Industrial Ethernet via ISO and TCP/IP, PROFINET IO controller or PROFINET IO device, integrated 2-port switch ERTEC 200, S7 communication, fetch/write, send/receive with and without RFC1006, Multicast DHCP, NTC- CPU Sync, diagnostic, initialization via LAN, 2x RJ45 connection for LAN with 10/100 Mbit/s |
Transmission rate |
Transfer rate | |
at the 1st interface | 10 ... 100 Mbit/s |
Interfaces |
Number of interfaces / acc. to Industrial Ethernet | 2 |
Number of electrical connections | |
at the 1st interface / acc. to Industrial Ethernet | 2 |
for power supply | 1 |
Type of electrical connection | |
at the 1st interface / acc. to Industrial Ethernet | RJ45 port |
of Industrial Ethernet interface | RJ45 port |
for power supply | 2-pole plugable terminal block |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage / 1 / from backplane bus | 5 V |
Supply voltage | 24 V |
Supply voltage / external | 24 V |
Supply voltage / external / at DC / Rated value | 24 V |
Relative positive tolerance / at DC / at 24 V | 20 % |
Relative negative tolerance / at DC / at 24 V | 15 % |
Consumed current | |
from backplane bus / at DC / at 5 V / typical | 0.2 A |
from external supply voltage / at DC / at 24 V / typical | 0.16 A |
from external supply voltage / at DC / at 24 V / maximum | 0.2 A |
Power loss [W] | 5.8 W |
Permitted ambient conditions |
Ambient temperature | |
for vertical installation / during operation | 0 ... 40 °C |
for horizontally arranged busbars / during operation | 0 ... 60 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight |
Module format | Compact module S7-300 single width |
Width | 40 mm |
Height | 125 mm |
Depth | 120 mm |
Net weight | 0.22 kg |
Mounting type | |
S7-300 rail mounting | Yes |
Performance data / open communication |
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 16 |
Amount of data | |
as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum | 2 Kibyte |
Number of Multicast stations | 16 |
Performance data / S7 communication |
Number of possible connections / for S7 communication | |
maximum | 16 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode | 32 |
Performance data / PROFINET communication / as PN IO-Controller |
Number of PN IO devices / on PROFINET IO controller / usable / total | 32 |
Number of external PN IO lines / with PROFINET / per rack | 1 |
Amount of data | |
as user data for input variables / as PROFINET IO controller / maximum | 1 Kibyte |
as user data for input variables / as PROFINET IO controller / maximum | 1 Kibyte |
as user data for input variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte |
as user data for output variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte |
as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte |
as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte |
Performance data / PROFINET communication / as PN IO-Device |
Product function / PROFINET IO device | Yes |
Amount of data | |
as user data for input variables / as PROFINET IO device / maximum | 512 byte |
as user data for input variables / as PROFINET IO device / maximum | 512 byte |
as user data for input variables / for each sub-module as PROFINET IO device | 240 byte |
as user data for input variables / for each sub-module as PROFINET IO device | 240 byte |
as user data for the consistency area for each sub-module | 240 byte |
Number of submodules / per PROFINET IO-Device | 32 |
Performance data / telecontrol |
Protocol / is supported | |
TCP/IP | Yes |
Product functions / management, configuration |
Product function / MIB support | Yes |
Protocol / is supported | |
SNMP v1 | Yes |
DCP | Yes |
LLDP | Yes |
Configuration software | |
required | STEP 7 V5.4 SP2 or higher / STEP 7 Professional V11 (TIA Portal) or higher |
Identification & maintenance function | |
I&M0 - device-specific information | Yes |
I&M1 – higher-level designation/location designation | Yes |
Product functions / Diagnosis |
Product function / Web-based diagnostics | Yes |
Product functions / switch |
Product feature / Switch | Yes |
Product function | |
switch-managed | No |
with IRT / PROFINET IO switch | Yes |
Configuration with STEP 7 | Yes |
Product functions / Redundancy |
Product function | |
Ring redundancy | Yes |
Redundancy manager | No |
Protocol / is supported / Media Redundancy Protocol (MRP) | Yes |
Product functions / Security |
Product function | |
password protection for Web applications | No |
ACL - IP-based | Yes |
ACL - IP-based for PLC/routing | No |
switch-off of non-required services | Yes |
Blocking of communication via physical ports | Yes |
log file for unauthorized access | No |
Product functions / Time |
Product function / SICLOCK support | Yes |
Product function / pass on time synchronization | Yes |
Protocol / is supported | |
NTP | Yes |