6GK6090-0AD2.-....
RUGGEDCOM RS900L

From SIEMENS

Product type designationRUGGEDCOM RS900L
RUGGEDCOM RS900L is an 8 port industrially hardened, fully managed Ethernet switch supporting EoVDSL allowing up to 5km LAN segments over telephone grade cable at up to 35Mbps. 128-bit Encryption; 6 fast Ethernet ports (10/100BaseTX); Optional: additional 2 fast Ethernet ports (10/100BaseTX or 100BaseFX) Ethernet ports (10/100BaseTX or 100BaseFX)
Transmission rate
Transfer rate10 Mbit/s, 100 Mbit/s
Transfer rate
with EoVDSL / maximum35 Mbit/s
Interfaces
Number of electrical/optical connections / for network components or terminal equipment / maximum9; 6 fast Ethernet ports (10/100BaseTX), 2 fast Ethernet fiber ports, and 1 EoVDSL port
Number of electrical connections
for network components or terminal equipment / maximum8
for EoVDSL / maximum1
Type of electrical connection
for power supplyterminal block
Number of optical interfaces / for network components or terminal equipment / maximum2
Range / at the optical interface / depending on the optical fiber used
minimum0.5 km
maximum90 km
Signal-Inputs/outputs
Relay designForm-C contact relay (CO, change over)
Operating current / of the signaling contacts / at DC / at 30 V / maximum2 A
Supply voltage, current consumption, power loss
Product options / wide range power supplyYes
Power loss [W]
maximum10 W
Supply voltage / 1 / Rated value24 V
Supply voltage / 1 / rated value10 ... 36 V
Type of voltage / 1 / of the supply voltageDC
Consumed current / 1 / at rated supply voltage / maximum0.4 A
Supply voltage / 2 / Rated value48 V
Supply voltage / 2 / rated value37 ... 72 V
Type of voltage / 2 / of the supply voltageDC
Consumed current / 2 / at rated supply voltage / maximum0.2 A
Supply voltage / 3 / Rated value
Supply voltage / 3 / rated value88 ... 300 V
Type of voltage / 3 / of the supply voltageDC
Supply voltage / 4 / Rated value
Supply voltage / 4 / rated value85 ... 264 V
Type of voltage / 4 / of the supply voltageAC
Permitted ambient conditions
Ambient temperature
during operation-40 ... +85 °C
NoteA maximum operating temperature of +85 °C is permissible for a duration of 16 hours
Coatingconformal coating optional
Operating condition / fanless operationYes
Protection class IPIP30
Design, dimensions and weight
Depth116.59 mm
Height187.96 mm
Width66.15 mm
Net weight1220 g
Material / of the enclosure20 AWG galvanized steel enclosure
Mounting type
35 mm DIN rail mountingYes
wall mountingYes
Product properties, functions, components / general
Product function
switch-managedYes
RAW socket mode for any serial protocolsNo
automatic selection of the fastest transfer rateYes
Switchover master or slave with softwareYes
Modbus RTU to Modbus TCP conversionYes
Protocol / is supported
TFTPNo
DNP3Yes
Modbus TCPYes
TINYes
WINYes
MicrolokYes
IGMP (snooping/querier)Yes
Number of groups / at IGMP256
Range / at VDSL interface / maximum5 km
Transmission mode / FDMYes
Storage capacity
of message buffer / maximum1 Mibyte
of the MAC-address table16 Kibyte
Switch latency period8 µs
Transfer rate / of the switch1.8 Gbit/s
Number of priority channels4
Product feature / Store & Forward switching methodYes
Product functions / management, configuration
Product function
CLIYes
web-based managementYes
RMONYes
MIB supportYes
Protocol / is supported
TelnetYes
HTTPYes
HTTPSNo
Product functions / Diagnosis
Protocol / is supported
SNMP v1Yes
SNMP v2cYes
SNMP v3Yes
Product functions / DHCP
Product function
DHCP clientYes
Product functions / VLAN
Number of VLANs / maximum255
Product function / VLAN - port basedYes
Protocol / is supported / GVRPYes
Product functions / Redundancy
Product function
redundancy procedure MSTPYes
redundancy procedure RSTPYes
eRSTPYes
Protocol / is supported / RSTPYes
Product functions / Security
Product function
port-rate-limitingYes
Adjustable port-rate-limitation128 kbit/s ... 8 Mbit/s
Product function
IEEE 802.1x (radius)Yes
Protocol / is supported
SSHYes
SSLYes
TACACS+Yes
Key length
with RSA1024 bit
Product functions / Time
Protocol / is supported
SNTPYes
Standards, specifications, approvals
Standard
for EMCFCC Part 15 (Class A), EN55022 (CISPR22 Class A)
for safety / from CSA and ULcCSAus (CSA C22.2 No. 60950, UL 60950, EN60950)
Laser protection class21 CFR Chapter 1, Subchapter J
Certificate of suitability
CE markingYes
relating to NEMATS 2
IEC 61850-3Yes
IEEE 1613Yes
Product conformity
RFC768-UDPYes
RFC783-TFTPYes
RFC791-IPYes
RFC792-ICMPYes
RFC793-TCPYes
RFC826-ARPYes
RFC854-TelnetYes
RFC894-IP over EthernetYes
RFC1112-IGMPv1Yes
RFC1519-CIDRYes
RFC2030-SNTPYes
RFC2068-HTTPYes
RFC2236-IGMPv2Yes
RFC2284-EAPYes
RFC2475-Differentiated ServiceYes
RFC2865-RADIUSYes
RFC3414-SNMPv3-USMYes
RFC3415-SNMPv3-VACMYes
RFC1541-DHCP (client)Yes
acc. to IEEE 802.3-10BaseTYes
acc. to IEEE 802.3u-100BaseTXYes
acc. to IEEE 802.3u-100BaseFXYes
acc. to IEEE 802.3x-Flow ControlYes
acc. to IEEE 802.3z-1000BaseLXYes
acc. to IEEE 802.3ab-1000BaseTYes
acc. to IEEE 802.3ad-Link AggregationYes
acc. to IEEE 802.1d-MAC BridgesYes
acc. to IEEE 802.1d-STPYes
acc. to IEEE 802.1p-class of serviceYes
acc. to IEEE 802.1Q-VLAN taggingYes
acc. to IEEE 802.1Q-2005 (formerly IEEE 802.1s) MSTPYes
acc. to IEEE 802.1x-port based Network Access ControlYes
acc. to IEEE 802.1D-2004-RSTPYes

External links