| SCALANCE XR124WG; Unmanaged IE switch; 19" rack; 24 x 10/100Mbit/s electrical ports; LED diagnostics; Power supply 240 V AC (85 – 264 V) |
Product type designation | SCALANCE XR124 |
Transmission rate |
Transfer rate | 10 Mbit/s, 100 Mbit/s |
Interfaces / for communication / integrated |
Number of electrical connections | |
for network components or terminal equipment | 24; RJ45 |
Number of 10/100 Mbit/s RJ45 ports / Integrated | 24 |
Interfaces / others |
Number of electrical connections | |
for power supply | 1 |
for redundant voltage supply | 1 |
Type of electrical connection | |
for power supply | 2-pole terminal block |
Supply voltage, current consumption, power loss |
Type of voltage supply / redundant power supply unit | No |
Type of voltage / of the supply voltage | AC |
Supply voltage | |
external | 240 V |
external / minimum | 85 V |
external / maximum | 264 V |
Product component / fusing at power supply input | Yes |
Fuse protection type / at input for supply voltage | 4 A / 250 V |
Consumed current / maximum | 0.075 A |
Power loss [W] | |
at AC / at 230 V | 7.5 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 0 ... 60 °C |
during storage | -40 ... +85 °C |
during transport | -40 ... +85 °C |
Relative humidity | |
at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP30 |
Design, dimensions and weight |
Design | 19" rack |
Width | 482.6 mm |
Height | 43.6 mm |
Depth | 177 mm |
Net weight | 3.3 kg |
Mounting type | |
19-inch installation | Yes |
35 mm DIN rail mounting | No |
wall mounting | No |
S7-300 rail mounting | No |
S7-1500 rail mounting | No |
Product properties, functions, components / general |
Cascading in cases of star topology | any (depending only on signal propagation time) |
Product functions / management, configuration |
Product function | |
multiport mirroring | No |
CoS | Yes |
Product function / switch-managed | No |
Product functions / Redundancy |
Product function | |
Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes |
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA) | No |
Standards, specifications, approvals |
Standard | |
for safety / from CSA and UL | UL 60950-1, CSA C22.2 No. 60950-1 |
for emitted interference | EN 61000-6-4 (Class B) |
for interference immunity | EN 61000-6-2 |
Standards, specifications, approvals / CE |
Certificate of suitability / CE marking | Yes |
Standards, specifications, approvals / miscellaneous |
Certificate of suitability | |
C-Tick | Yes |
Railway application in accordance with EN 50155 | No |
related to FCC | T |
FCC, Part 15, Section B, Class b | Yes |
KC approval | Yes |