6GK1561-2AA00
Communication processor CP 5612

From SIEMENS

Product type designationCP 5612
Communications processor CP 5612 PCI card for connection connection of a PG or PC with PCI bus to PROFIBUS or MPI usable in 32 bit and 64 bit operating systems see also entry ID 22611503
Transmission rate
Transfer rate
at the 1st interface / acc. to PROFIBUS9.6 kbit/s ... 12 Mbit/s
Interfaces
Number of electrical connections
at the 1st interface / acc. to PROFIBUS1
Type of electrical connection
at the 1st interface / acc. to PROFIBUS9-pin Sub-D socket (RS 485)
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltageDC
Supply voltage
1 / from backplane bus3.3 V
2 / from backplane bus12 V
Relative symmetrical tolerance / at DC
at 3.3 V9 %
at 12 V8 %
Consumed current
1 / from backplane bus / at DC / maximum0.15 A
2 / from backplane bus / at DC / maximum0.25 A
Power loss [W]3.5 W
Permitted ambient conditions
Ambient temperature
during operation5 ... 55 °C
during storage-20 ... +60 °C
during transport-20 ... +60 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum95 %
Protection class IPIP00
Design, dimensions and weight
Module formatPCI
Width18 mm
Height107 mm
Depth125 mm
Net weight98 g
Number of plug-in cards of same design / plug-in / per PC station1
Number of units / Note-
Performance data
Performance data / open communication
Software / for open communication / by means of SEND/RECEIVE / requiredYes, SOFTNET-PB DP / SOFTNET-PB DP Slave / SOFTNET-PB S7
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum50
Performance data / PROFIBUS DP
Software / for DP master function / requiredYes, SOFTNET-PB DP
Service / as DP master
DPV0Yes
DPV1Yes
DPV2No
Number of DP slaves / on DP master / usable64
Amount of data
of the address area of the inputs / as DP master / total14640 byte
of the address area of the outputs / as DP master / total14640 byte
of the address area of the inputs / per DP slave244 byte
of the address area of the outputs / per DP slave244 byte
of the address area of the diagnostic data / per DP slave244 byte
Software / for DP slave function / requiredYes, SOFTNET-PB DP slave
Service / as DP slave
DPV0Yes
DPV1No
Amount of data
of the address area of the inputs / as DP slave / total122 byte
of the address area of the outputs / as DP slave / total122 byte
Performance data / S7 communication
Software / for S7 communication / requiredYes, SOFTNET-PB S7
Number of possible connections / for S7/PG communication / maximum8
Performance data / multi-protocol mode
Number of configurable connections / per PC station207
Product functions / management, configuration
Configuration software / requiredIncluded in the scope of delivery of the required software product
Product functions / Diagnosis
Product function
Port diagnosticsYes
Standards, specifications, approvals
Standard
for EMC89/336/EEC
for safety / from CSA and ULCAN/CSA C22.2 & UL 60950-1, UL 1950
for emitted interferenceEN 61000-6-3
for interference immunityEN 61000-6-2
Certificate of suitability
CE markingYes
C-TickYes
Accessories
accessoriesoptional: MPI cable