6GK1551-2AA00
COMMUNICATION PROCESSOR CP 5512

From SIEMENS

Product type designationCP 5512
Communications processor CP 5512 PC Card (Cardbus, 32 Bit) for connection of a PG or Notebook to PROFIBUS or MPI;
Transmission rate
Transfer rate
at the 1st interface / acc. to PROFIBUS9.6 kbit/s ... 12 Mbit/s
Interfaces
Number of electrical connections
at the 1st interface / acc. to PROFIBUS1
Type of electrical connection
at the 1st interface / acc. to PROFIBUS9-pin Sub-D socket (RS 485)
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltageDC
Supply voltage
1 / from backplane bus3.3 V
Relative symmetrical tolerance / at DC
at 3.3 V5 %
Consumed current
1 / from backplane bus / at DC / maximum0.52 A
Power loss [W]1.8 W
Permitted ambient conditions
Ambient temperature
during operation5 ... 45 °C
during storage-20 ... +60 °C
during transport-20 ... +60 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum95 %
Protection class IPIP00
Design, dimensions and weight
Module formatPC card Type II CardBus (32 bit)
Width86 mm
Height5 mm
Depth54 mm
Net weight130 g
Number of plug-in cards of same design / plug-in / per PC station1
Number of units / Note-
Performance data
Performance data / open communication
Software / for open communication / by means of SEND/RECEIVE / requiredYes, SOFTNET-PB DP / SOFTNET-PB DP Slave / SOFTNET-PB S7
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum50
Performance data / PROFIBUS DP
Software / for DP master function / requiredYes, SOFTNET-PB DP
Service / as DP master
DPV0Yes
DPV1No
DPV2No
Number of DP slaves / on DP master / usable64
Amount of data
of the address area of the inputs / as DP master / total7808 byte
of the address area of the outputs / as DP master / total7808 byte
of the address area of the inputs / per DP slave244 byte
of the address area of the outputs / per DP slave244 byte
of the address area of the diagnostic data / per DP slave244 byte
Software / for DP slave function / requiredYes, SOFTNET-PB DP slave
Service / as DP slave
DPV0Yes
DPV1No
Amount of data
of the address area of the inputs / as DP slave / total122 byte
of the address area of the outputs / as DP slave / total122 byte
Performance data / S7 communication
Software / for S7 communication / requiredYes, SOFTNET-PB S7
Number of possible connections / for S7/PG communication / maximum8
Performance data / multi-protocol mode
Number of configurable connections / per PC station207
Product functions / management, configuration
Configuration software / requiredIncluded in the scope of delivery of the required software product
Product functions / Diagnosis
Product function
Port diagnosticsYes
Standards, specifications, approvals
Standard
for EMC2004/108/EC
for safety / from CSA and ULCAN/CSA C22.2 & UL 60950-1
for emitted interferenceEN 61000-6-3, EN 61000-6-4
for interference immunityEN 61000-6-1, EN 61000-6-2
Certificate of suitability
CE markingYes
C-TickYes