6ES7317-6TK13-0AB0
CPU317T-2 DP, 1024KB

From SIEMENS

***Spare part*** SIMATIC S7-300, CPU 317T-2 DP, Central processing unit for PLC and Technology tasks, 1024 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP (drive), Integr. I/O for technology Front connector (1x 40-pole) and Micro Memory Card min. 8 MB required
General information
HW functional status01
Firmware versionCPU: V2.7, integrated technology: V4.1.5
Engineering with
Programming packageSTEP 7 V5.4 + SP5 (and higher) and Optional package  S7-Technology V4.2
Supply voltage
Rated value (DC)
24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Load voltage L+
Rated value (DC)24 V
Reverse polarity protectionYes
Digital outputs
— Rated value (DC)24 V; (2L+)
— Reverse polarity protectionNo; (2L+)
Input current
Current consumption (in no-load operation), typ.200 mA
Inrush current, typ.2.5 A
I²t1 A²·s
Power loss
Power loss, typ.6 W
Memory
Work memory
integrated1 024 kbyte
expandableNo
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 y
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.05 µs
for bit operations, max.0.05 µs
for word operations, typ.0.2 µs
for fixed point arithmetic, typ.0.2 µs
for floating point arithmetic, typ.1 µs
CPU-blocks
Number of blocks (total)2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.2 047; Number band: 1 to 2047
Size, max.64 kbyte
FB
Number, max.2 048; Number range: 0 to 2047
Size, max.64 kbyte
FC
Number, max.2 048; Number range: 0 to 2047
Size, max.64 kbyte
OB
Descriptionsee instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number of isochronous mode OBs1; OB 61
Number of technology synchronous alarm OBs1; OB 65
Number of startup OBs1; OB 100
Number of asynchronous error OBs5; OB 80, 82, 85, 86, 87
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number512; Number range: 0 to 511
Retentivity
— adjustableYes
— preset8
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number512; Number range: 0 to 511
Retentivity
— adjustableYes
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in totalAll DBs, max. 256 KB
Flag
Number, max.4 096 byte
Retentivity availableYes; From MB 0 to MB 4 095
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.1 024 byte
Address area
I/O address area
Inputs8 192 byte
Outputs8 192 byte
of which distributed
— Inputs8 192 byte
— Outputs8 192 byte
Process image
Inputs, adjustable2 048 byte
Outputs, adjustable2 048 byte
Inputs, default256 byte
Outputs, default256 byte
Default addresses of the integrated channels
— Digital inputs66
— Digital outputs66
Subprocess images
Number of subprocess images, max.1
Digital channels
Inputs65 536
— of which central512
Outputs65 536
— of which central512
Analog channels
Inputs4 096
— of which central64
Outputs4 096
— of which central64
Hardware configuration
Number of expansion units, max.0
Number of DP masters
integrated2; 1 DP and 1 DP (drive)
via CP2; for DP
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.1
Modules per rack, max.8
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s
Operating hours counter
Number4
Number/Number range0 to 3
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
Digital inputs
Number of digital inputs4
of which inputs usable for technological functions4
Input characteristic curve in accordance with IEC 61131, type 1Yes
Number of simultaneously controllable inputs
horizontal installation
— up to 40 °C, max.4
— up to 60 °C, max.4
vertical installation
— up to 40 °C, max.4
Input voltage
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+15 to +30V
Input current
for signal "1", typ.7 mA
Input delay (for rated value of input voltage)
for technological functions
— at "0" to "1", max.10 µs; Typical
— at "1" to "0", max.10 µs; Typical
Cable length
shielded, max.1 000 m
Digital outputs
Number of digital outputs8
of which high-speed outputs8
FunctionsFor technology functions, e.g. high-speed cam switch signals
Short-circuit protectionYes
Response threshold, typ.1 A
Limitation of inductive shutdown voltage to48 V
Controlling a digital inputNo
Switching capacity of the outputs
on lamp load, max.5 W
Load resistance range
lower limit48 Ω
upper limit4 kΩ
Output voltage
for signal "0", max.3 V; (2L+)
for signal "1", min.Rated voltage -2.5 V
Output current
for signal "1" rated value0.5 A
for signal "1" permissible range for 0 to 60 °C, min.5 mA
for signal "1" permissible range for 0 to 60 °C, max.0.6 A
for signal "0" residual current, max.0.3 mA
Parallel switching of two outputs
for upratingNo
for redundant control of a loadNo
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.0.2 Hz; According to IEC 60947-5-1, DC-13
on lamp load, max.100 Hz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max.4 A
— up to 60 °C, max.3 A
all other mounting positions
— up to 40 °C, max.3 A
Cable length
shielded, max.1 000 m
Analog inputs
Number of analog inputs0
Analog outputs
Number of analog outputs0
Encoder
Connectable encoders
2-wire sensorNo
Interfaces
Number of industrial Ethernet interfaces0
Number of PROFINET interfaces0
Number of RS 485 interfaces2
Number of RS 422 interfaces0
1. Interface
Interface typeIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
Point-to-point connectionNo
MPI
Number of connections32
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes; Connection configured on one side only
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes; Connection configured on one side only
— EquidistanceYes
— Isochronous modeYes; OB 61
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— DPV1Yes
Address area
— Inputs, max.8 192 byte
— Outputs, max.8 192 byte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP slave
Transmission rate, max.12 Mbit/s
automatic baud rate searchNo
Address area, max.32
User data per address area, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; Only with active interface
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typeIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Protocols
MPINo
PROFIBUS DP masterYes; DP(DRIVE)-Master
PROFIBUS DP slaveNo
Point-to-point connectionNo
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.64
Services
— PG/OP communicationNo
— RoutingNo
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationNo
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZENo
— Activation/deactivation of DP slavesYes
— DPV1No
Address area
— Inputs, max.1 024 byte
— Outputs, max.1 024 byte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP slave
GSD file
Transmission rate, max.12 Mbit/s
Communication functions
PG/OP communicationYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV), 76 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; Via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
supportedYes; via CP and loadable FC
Number of connections
overall32
usable for PG communication31
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.31
usable for OP communication31
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.31
usable for S7 basic communication30
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.30
usable for routing8; additional
S7 message functions
Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.60
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints2
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.100
— adjustableNo
Interrupts/diagnostics/status information
AlarmsNo
Diagnostics functionNo
Diagnostics indication LED
Status indicator digital input (green)Yes
Status indicator digital output (green)Yes
Potential separation
Potential separation digital inputs
between the channels and backplane busYes
Potential separation digital outputs
between the channels and backplane busYes
Permissible potential difference
between different circuits75 V DC/60 V AC
Isolation
Isolation tested with500 V DC
Ambient conditions
Ambient temperature during operation
min.0 °C
max.60 °C
Configuration
Configuration software
STEP 7Yes
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Cycle time monitoring
lower limit1 ms
upper limit6 000 ms
adjustableYes
preset150 ms
Dimensions
Width160 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.750 g
last modified:03/13/2019