6ES7317-2EJ10-0AB0
CPU317-2 PN/DP, 512KB

From SIEMENS

SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 512 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, MICRO MEMORY CARD NECESSARY
General information
HW functional status02
Firmware versionV2.3.0
Engineering with
Programming packageSTEP 7 V5.3 or higher
Supply voltage
Rated value (DC)
24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Input current
Current consumption (rated value)650 mA
Current consumption (in no-load operation), typ.100 mA
Inrush current, typ.2.5 A
I²t1 A²·s
Power loss
Power loss, typ.3.5 W
Memory
Work memory
integrated512 kbyte
expandableNo
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 y
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.05 µs
for bit operations, max.0.05 µs
for word operations, typ.0.2 µs
for fixed point arithmetic, typ.0.2 µs
for floating point arithmetic, typ.1 µs
CPU-blocks
Number of blocks (total)2 048; (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used.
DB
Number, max.2 047; Number band: 1 to 2047
Size, max.64 kbyte
FB
Number, max.2 048; Number range: 0 to 2047
Size, max.64 kbyte
FC
Number, max.2 048; Number range: 0 to 2047
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of startup OBs1; OB 100
Number of asynchronous error OBs1; OB 80
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number512
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number512
Retentivity
— adjustableYes
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in totalall, max. 256 KB
Flag
Number, max.4 096 byte
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Address area
I/O address area
Inputs8 kbyte
Outputs8 kbyte
Process image
Inputs256 byte
Outputs256 byte
Inputs, adjustable2 048 kbyte
Outputs, adjustable2 048 kbyte
Inputs, default256 byte
Outputs, default256 byte
Digital channels
Inputs65 536
— of which central1 024
Outputs65 536
— of which central1 024
Analog channels
Inputs4 096
— of which central256
Outputs4 096
— of which central256
Hardware configuration
Number of DP masters
integrated1
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.4
Modules per rack, max.8
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s
Operating hours counter
Number4
Number/Number range0 to 3
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
in AS, masterYes
in AS, slaveYes
1. Interface
Interface typeIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
Point-to-point connectionNo
MPI
Number of connections16
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
— EquidistanceYes
— SYNC/FREEZEYes
— DPV1Yes
Address area
— Inputs, max.244 kbyte
— Outputs, max.244 kbyte
PROFIBUS DP slave
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
Services
— RoutingYes; with interface active
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typePROFINET
PhysicsRJ45
IsolatedYes
Power supply to interface (15 to 30 V DC), max.0 mA
automatic detection of transmission rateYes; 10/100 Mbit/s
Protocols
MPINo
PROFINET IO ControllerYes; Firmware version V2.3 and higher
PROFINET CBAYes
PROFIBUS DP masterNo
PROFIBUS DP slaveNo
Point-to-point connectionNo
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— S7 communicationYes; with loadable FBs, max. configurable connections: 16
— Open IE communicationYes; via TCP/IP
— Number of connectable IO Devices, max.128
— Updating time1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
— User data consistency, max.256 byte
PROFINET CBA
acyclic transmissionYes
cyclic transmissionYes
Protocols
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.1 460 byte
Communication functions
PG/OP communicationYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
supportedYes; via CP and loadable FC
PROFINET CBA (at set setpoint communication load)
Setpoint for the CPU communication load50 %
Number of remote interconnection partners32
Number of functions, master/slave17
Total of all master/slave connections1 000
Data length of all incoming connections master/slave, max.4 000 byte
Data length of all outgoing connections master/slave, max.4 000 byte
Number of device-internal and PROFIBUS interconnections500
Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
Data length per connection, max.1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min.500 ms
— Number of incoming interconnections100
— Number of outgoing interconnections100
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
— Data length per connection, max.1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min.10 ms
— Number of incoming interconnections200
— Number of outgoing interconnections200
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
— Data length per connection, max.450 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
— HMI variable updating500 ms
— Number of HMI variables200
— Data length of all HMI variables, max.2 000 byte
PROFIBUS proxy functionality
— supportedYes
— Number of linked PROFIBUS devices16
— Data length per connection, max.240 byte; Slave-dependent
Number of connections
overall32
usable for PG communication31
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.31
usable for OP communication31
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.31
usable for S7 basic communication30
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.30
S7 message functions
Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.60
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints2
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.100
Configuration
Configuration software
STEP 7Yes; V5.3 or higher
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Dimensions
Width80 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.460 g
last modified:02/21/2020