| *** SPARE PART*** SIMATIC S7-300, CPU 314 IFM COMPACT CPU WITH MPI, FOR EXPANDED TEMPERATURE RANGE, 16DI/16DO, 4AI/1AO, 2 X 40 PIN, INTEGRATED 24V DC POWER SUPPLY, 32 KBYTE WORKING MEMORY |
Supply voltage |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Load voltage L+ |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Input current |
Current consumption (rated value) | 1 000 mA |
Inrush current, typ. | 8 A |
Power loss |
Power loss, typ. | 16 W |
Memory |
Work memory |
integrated | 32 kbyte; 32 KB/10 K instructions RAM (integrated); 1 instruction means 3 bytes on average |
Load memory |
integrated RAM, max. | 48 kbyte |
Backup |
with battery | Yes; all blocks |
without battery | Yes; 144 bytes: Bit memories, counters, timers and data |
CPU processing times |
for bit operations, typ. | 0.3 µs |
for bit operations, max. | 0.6 µs |
for word operations, typ. | 1 µs |
for fixed point arithmetic, typ. | 2 µs |
for floating point arithmetic, typ. | 50 µs |
for timer/counter operations, typ. | 12 µs |
CPU-blocks |
DB |
Number, max. | 127 |
Size, max. | 8 kbyte |
FB |
Number, max. | 128 |
Size, max. | 8 kbyte |
FC |
Number, max. | 128 |
Size, max. | 8 kbyte |
OB |
Description | see instruction list |
Size, max. | 8 kbyte |
Number of free cycle OBs | 1; OB 1 |
Number of time alarm OBs | 1; OB 10 |
Number of cyclic interrupt OBs | 1; OB 35 |
Number of process alarm OBs | 1; OB 40 |
Number of startup OBs | 1; OB 100 |
Nesting depth |
per priority class | 8 |
Counters, timers and their retentivity |
S7 counter |
Number | 64 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 63 |
Counting range |
— lower limit | 1 |
— upper limit | 999 |
S7 times |
Number | 128 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 71 |
Time range |
— lower limit | 10 ms |
— upper limit | 9 990 s |
Data areas and their retentivity |
Flag |
Number, max. | 256 byte |
Retentivity available | Yes; MB 0 to MB 255 |
of which retentive with battery | 0 to 2 047 (M 0.0 to M 255.7, adjustable) |
of which retentive without battery | 0 to 1 152 (M 0.0 toM 143.7, adjustable) |
Address area |
I/O address area |
Inputs | 512 byte |
Outputs | 512 byte |
Process image |
Inputs | 128 byte |
Outputs | 128 byte |
Digital channels |
Inputs | 992 |
Outputs | 992 |
Analog channels |
Inputs | 248 |
Outputs | 124 |
Addressing volume |
Inputs | 122 byte |
Outputs | 122 byte |
Address space per module |
Address space per module, max. | 512 byte; 512 byte / 512 byte |
Hardware configuration |
Number of expansion units, max. | 3 |
connectable programming devices/PCs | PGs/PCs with STEP 7 connectable via MPI interface |
Number of modules per DP slave interface, max. | 16 |
Number of DP masters |
via CP | 1; CP 342-5 |
Number of operable FMs and CPs (recommended) |
FM | 4 |
CP, PtP | 2 |
CP, LAN | 1 |
Rack |
Modules per rack, max. | 31 |
Time of day |
Clock |
Hardware clock (real-time) | Yes |
Digital inputs |
Number of digital inputs | 20; of which 4 channels can be used for process alarms or integrated functions |
Input voltage |
Rated value (DC) | 24 V |
for signal "0" | -3 to +5V |
for signal "1" | +15 to +30V |
Input current |
for signal "1", typ. | 7 mA; Min. 2 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— at "0" to "1", max. | 5 ms; typically 3 ms |
for interrupt inputs |
— at "0" to "1", max. | 50 µs |
for technological functions |
— at "0" to "1", max. | 50 µs |
Cable length |
shielded, max. | 1 000 m; 100 m for alarm and counter inputs |
unshielded, max. | 600 m |
Digital outputs |
Number of digital outputs | 16 |
Short-circuit protection | Yes; Clocked electronically |
Limitation of inductive shutdown voltage to | 30 V |
Output voltage |
for signal "1", min. | L+ (-0.8 V) |
Output current |
for signal "1" permissible range for 0 to 60 °C, max. | 500 mA |
for signal "1" minimum load current | 5 mA |
for signal "0" residual current, max. | 0.5 mA |
Switching frequency |
with resistive load, max. | 100 Hz |
with inductive load, max. | 0.5 Hz |
Total current of the outputs (per group) |
all mounting positions |
— up to 40 °C, max. | 4 A |
— up to 60 °C, max. | 2 A |
Cable length |
shielded, max. | 1 000 m |
unshielded, max. | 600 m |
Analog inputs |
Number of analog inputs | 4 |
Input ranges |
Voltage | Yes |
Current | Yes |
Input ranges (rated values), currents |
-20 mA to +20 mA | Yes |
Input resistance (-20 mA to +20 mA) | 105.5 kΩ |
Analog outputs |
Number of analog outputs | 1 |
Output ranges, voltage |
-10 V to +10 V | Yes |
Output ranges, current |
-20 mA to +20 mA | Yes |
Analog value generation for the inputs |
Integration and conversion time/resolution per channel |
Resolution with overrange (bit including sign), max. | 12 bit |
Conversion time (per channel) | 100 µs |
Analog value generation for the outputs |
Integration and conversion time/resolution per channel |
Resolution with overrange (bit including sign), max. | 12 bit |
Conversion time (per channel) | 40 µs |
Encoder |
Connectable encoders |
2-wire sensor | Yes |
— permissible quiescent current (2-wire sensor), max. | 1.5 mA |
Errors/accuracies |
Basic error limit (operational limit at 25 °C) |
Voltage, relative to input range, (+/-) | 0.9 % |
Current, relative to input range, (+/-) | 0.9 % |
Voltage, relative to output range, (+/-) | 0.9 % |
Current, relative to output range, (+/-) | 0.9 % |
Interfaces |
MPI |
Cable length, max. | 9 100 m; Distance between 2 neighboring nodes, max. - without repeaters: 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with 16 star hubs or OLMs) |
PROFIBUS DP |
Number of stations per segment, max. | 16 |
1. Interface |
Protocols |
MPI | Yes |
MPI |
Number of nodes, max. | 32; 32 nodes on MPI bus; PG/PC, OP, additional S7-300/400, C7; per CPU max. 4 static and 4 dynamic connections |
Transmission rate, max. | 187.5 kbit/s |
Services |
— PG/OP communication | Yes |
— Global data communication | Yes |
— S7 basic communication | Yes |
— S7 communication | Yes |
Communication functions |
PG/OP communication | Yes |
Global data communication |
supported | Yes |
S7 basic communication |
supported | Yes |
S7 communication |
supported | Yes |
as server | Yes |
S5 compatible communication |
supported | Yes; via loadable blocks |
Standard communication (FMS) |
supported | Yes; via loadable blocks |
Number of connections |
overall | |
— of which dynamic | 8 |
— of which static | 4 |
Integrated Functions |
Number of counters | 2; 1 counter with 4 inputs or 2 counters with 2 inputs and 2 direction-dependent comparators for each counter; counter frequency 10 kHz; 32 bit (incl. sign) |
Counting frequency (counter) max. | 10 kHz |
Frequency measurement | Yes; 1 channel to max. 10 kHz; measurement times 0.1 s, 1 s, 10 s; meas. procedure: calculation of pulse number per meas. time |
controlled positioning | Yes; 1 channel; position detection via a 24 V asymmetrical incremental encoder; 3 digital inputs are occupied by the encoder (track A, track B, reference point); simple evaluation of the counting pulses (10 kHz) |
PID controller | Yes; PID closed-loop control function blocks: Continuous controller outputs, binary controller outputs, automatic/manual mode, setpoint limitation |
Potential separation |
Potential separation digital inputs |
between the channels, in groups of | 16; Special inputs in groups of 4, inputs in groups of 16 |
between the channels and backplane bus | Yes |
Potential separation digital outputs |
between the channels, in groups of | 8 |
between the channels and backplane bus | Yes |
Potential separation analog inputs |
between the channels, in groups of | 4 |
between the channels and backplane bus | Yes |
Potential separation analog outputs |
between the channels, in groups of | 1 |
between the channels and backplane bus | Yes |
Ambient conditions |
Ambient temperature during operation |
min. | -25 °C |
max. | 60 °C |
Configuration |
Configuration software |
STEP 7 | Yes; V5.0 SP1 |
Programming |
Command set | Binary logic operations, bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions |
Nesting levels | 8 |
Program processing | free cycle (OB 1), time-controlled (OB 35), clock-time controlled (OB 10), interrupt controlled (OB 40), startup (OB 100) |
Program organization | Linear, structured |
System functions (SFC) | Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions |
Programming language |
— SCL | Yes |
— GRAPH | Yes |
Software libraries |
— Process diagnostics | Yes |
— Software controller | Yes; depending on the required memory space and the resulting execution time |
Know-how protection |
User program protection/password protection | Yes |
Cycle time monitoring |
lower limit | 1 ms |
upper limit | 6 000 ms |
adjustable | Yes |
preset | 150 ms |
Dimensions |
Width | 160 mm |
Height | 125 mm |
Depth | 130 mm |
Weights |
Weight, approx. | 900 g |
last modified: | 03/13/2019 |