| Active field distributor AFDiS FISCO field barrier for PROFIBUS PA for Foundation Fieldbus H1 6 short circuit-proof and intrinsically safe spur lines with bounce protection logic Integrated field bus repeater Automatic bus termination for line and ring topology for extended temperature range Degree of protection IP66 |
General information |
Product type designation | Active field distributor |
HW functional status | 01 |
Product function |
Repeater function | Yes |
Supply voltage |
Design of the power supply | via fieldbus |
permissible range, lower limit (DC) | 16 V |
permissible range, upper limit (DC) | 32 V |
Reverse polarity protection | Yes; only in conjunction with FDC 157 |
Overvoltage protection | No |
Input current |
Current consumption, max. | 400 mA; at 20 V input voltage |
Current consumption in the case of short-circuit at all spur lines | 100 mA; at 24 V input voltage |
Power loss |
Power loss, typ. | 1.4 W; minimum - typ. specification not possible because load-dependent |
Power loss, max. | 5.9 W |
Interfaces |
PROFIBUS PA |
Transmission rate, max. | 31.25 kbit/s |
Number of connectable PA field devices | 6 |
Current output to PA field devices, max. | 260 mA |
permissible current per spur line | 40 mA; first spur line 60 mA |
Protocols |
PROFIBUS DP | No |
PROFIBUS PA | Yes |
AS-Interface | No |
FOUNDATION Fieldbus H1 | Yes |
Interrupts/diagnostics/status information |
Status indicator | Yes |
Alarms | No |
Diagnostics function | Yes |
Diagnostics indication LED |
Main line status | Yes |
Main line failure | Yes |
Spur line status/fault | Yes |
automatic bus termination | Yes |
Potential separation |
between main line and spur lines | Yes |
Isolation |
Isolation tested with | 2 550 V DC |
Degree and class of protection |
Degree of protection acc. to EN 60529 | |
IP66 | Yes |
Standards, approvals, certificates |
Use in hazardous areas |
ATEX Zone 1 | Yes |
ATEX Zone 21 | Yes |
ATEX Zone 2 | Yes |
ATEX Zone 22 | Yes |
FM Class I Zone 1 | Yes |
FM Class I Zone 2, Division 2 | Yes |
Type of protection acc. to KEMA | 10 ATEX 0055 |
Test number KEMA | 10 ATEX 0055 |
Ambient conditions |
Ambient temperature during operation |
min. | -40 °C |
max. | 70 °C |
Ambient temperature during storage/transportation |
min. | -40 °C |
max. | 70 °C |
Relative humidity |
Operation, max. | 95 % |
Connection method |
Main line |
Number of main lines | 2 |
Design of terminals | Screw terminal block |
Type of connection (enclosure cable gland) | M16 |
Type of cable | Type A |
Cable diameter, min. | 4 mm |
Cable diameter, max. | 9 mm |
Conductor cross-section, min. | 0.2 mm² |
Conductor cross-section, max. | 2.5 mm² |
automatic bus termination | Yes |
permissible main line current | 1 A |
Spur line |
Number of spur lines | 6 |
Design of terminals | Screw terminal block |
Type of connection (enclosure cable gland) | M16 |
Type of cable | Type A |
Cable diameter, min. | 4 mm |
Cable diameter, max. | 9 mm |
Conductor cross-section, min. | 0.2 mm² |
Conductor cross-section, max. | 2.5 mm² |
total current output to field devices, max. | 260 mA |
Number of connectable field devices | 6 |
Current limitation per field device, max. | 40 mA; 60 mA on S1 |
No-load voltage, max. | 15.3 V; on spur lines |
short-circuit proof | Yes |
Short-circuit current (test current); max. | 5 mA; on spur lines |
intrinsically safe according to FISCO model | Yes |
Debounce logic | Yes |
Dimensions |
Width | 380 mm |
Height | 85 mm |
Depth | 170 mm |
Weights |
Weight, approx. | 4 500 g |
last modified: | 03/13/2019 |