| SIMATIC DP, interface DP/PA-Link and ET200M IM153-2 HF for extended temperature range for max. 12 S7-300 modules with redundancy capability, Timestamping suitable for isochronous mode New features: up to 12 modules can be used Slave Initiative for Drive ES and Switch ES Expanded quantity structure for HART auxiliary variables Operation of the 64-channel modules 32 signals / slot +++ Observe compatibility instructions in manual +++ |
General information |
Product type designation | IM 153-2 HF |
Firmware version | V6.0.0 |
Vendor identification (VendorID) | 801Eh |
Supply voltage |
Rated value (DC) | |
24 V DC | Yes |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
external protection for power supply lines (recommendation) | 2,5 A |
Mains buffering |
Mains/voltage failure stored energy time | 5 ms |
Input current |
Current consumption, max. | 650 mA |
Inrush current, typ. | 3 A |
I²t | 0.1 A²·s |
Output current |
for backplane bus (5 V DC), max. | 1.5 A |
Power loss |
Power loss, typ. | 5.5 W |
Address area |
Addressing volume |
Inputs | 244 byte |
Outputs | 244 byte |
Hardware configuration |
Number of modules per DP slave interface, max. | 12 |
Time stamping |
Accuracy | 1 ms; 1ms at up to 8 modules; 10ms at up to 12 modules |
Number of message buffers | 15 |
Messages per message buffer | 20 |
Number of stampable digital inputs, max. | 128; Max. 128 signals/station; max. 32 signals/slot |
Time format | RFC 1119 |
Time resolution | 0.466 ns |
Time interval for transmitting the message buffer if a message is present | 1 000 ms |
Time stamp on signal change | rising / falling edge as signal entering or exiting |
Interfaces |
Transmission procedure | RS 485 |
PROFIBUS DP |
Node addresses | 1 to 125 permitted |
automatic detection of transmission rate | Yes |
Output current, max. | 70 mA |
Transmission rate, max. | 12 Mbit/s |
SYNC capability | Yes |
FREEZE capability | Yes |
Direct data exchange (slave-to-slave communication) | Yes; as publisher with all IO, as subscriber with F-IO only |
Design of electrical connection of PROFIBUS interface | 9-pin sub D |
1. Interface |
PROFIBUS DP slave |
GSD file | SI05801E.GSG |
automatic baud rate search | Yes |
Protocols |
Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 |
Potential separation |
Potential separation exists | Yes |
Isolation |
Isolation tested with | Isolation voltage 500 V |
Degree and class of protection |
IP degree of protection | IP20 |
Ambient conditions |
Altitude during operation relating to sea level |
Installation altitude above sea level, max. | 3 000 m |
Configuration |
Configuration software |
STEP 7 | Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file |
Dimensions |
Width | 40 mm |
Height | 125 mm |
Depth | 117 mm |
Weights |
Weight, approx. | 360 g |
last modified: | 03/29/2019 |