6ES7151-8AB00-0AB0
ET 200S, IM151-8 PN/DP CPU, 128 KB

From SIEMENS

***Spare part*** SIMATIC DP, IM151-8 PN/DP CPU f. ET200S, 128 KB work memory int. PROFINET interface (with three RJ45 ports) as IO controller,without battery MMC required
General information
HW functional status01
Firmware versionV2.7
Engineering with
Programming packageSTEP 7 V5.4 SP4 or higher
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes; against destruction
external protection for power supply lines (recommendation)24 V DC/16 A miniature circuit breaker with type B and C tripping characteristics. Note: The 24 V DC/16 A miniature circuit breaker with type B tripping characteristics trips before the device protection fuse. The 24 V DC/16 A miniature circuit breaker with type C tripping characteristics trips
Mains buffering
Mains/voltage failure stored energy time5 ms
Input current
Inrush current, max.1.8 A; Typical
I²t0.21 A²·s
from supply voltage 1L+, max.380 mA; 460 mA with DP master module
Output current
for backplane bus (5 V DC), max.700 mA
Power loss
Power loss, typ.5.5 W
Memory
Work memory
integrated128 kbyte; For program and data
expandableNo
Size of retentive memory for retentive data blocks64 kbyte
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 y
Backup
presentYes; Ensured by SIMATIC Micro Memory Card (maintenance-free)
CPU processing times
for bit operations, typ.0.1 µs
for word operations, typ.0.2 µs
for fixed point arithmetic, typ.2 µs
for floating point arithmetic, typ.3 µs
CPU-blocks
Number of blocks (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.511; Number range: 1 to 511
Size, max.64 kbyte
FB
Number, max.1 024; Number range: 0 to 2047
Size, max.64 kbyte
FC
Number, max.1 024; Number range: 0 to 2047
Size, max.64 kbyte
OB
DescriptionSee S7-300 operation list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs1; OB 20
Number of cyclic interrupt OBs1; OB 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number of startup OBs1; OB 100
Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO)
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number256
Retentivity
— adjustableYes
— lower limit0
— upper limit255
— presetZ 0 to Z 7
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number256
Retentivity
— adjustableYes
— lower limit0
— upper limit255
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Flag
Number, max.256 byte
Retentivity availableYes
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.510 byte; per priority class
Address area
I/O address area
Inputs2 048 byte
Outputs2 048 byte
of which distributed
— Inputs2 048 byte
— Outputs2 048 byte
Process image
Inputs, adjustable2 048 byte
Outputs, adjustable2 048 byte
Inputs, default128 byte
Outputs, default128 byte
Subprocess images
Number of subprocess images, max.none
Digital channels
Inputs16 336
— of which central496
Outputs16 336
— of which central496
Analog channels
Inputs1 021
— of which central124
Outputs1 021
— of which central124
Hardware configuration
Number of modules per system, max.63; Centralized
Mounting rail
Number of mounting rails that can be used1
Length of mounting rail, max.Station width: ≤ 1 m or < 2 m
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s
Behavior of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
Operating hours counter
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterNo
to MPI, slaveNo
to DP, masterYes; With DP master module
to DP, slaveYes; With DP master module
in AS, masterNo
in AS, slaveNo
on Ethernet via NTPYes; As client
Interfaces
Number of industrial Ethernet interfaces1
Number of PROFINET interfaces1
Number of wireless interfaces0
1. Interface
Interface typePROFINET
PhysicsEthernet
IsolatedYes
automatic detection of transmission rateYes
AutonegotiationYes
AutocrossingYes
Interface types
Number of ports3; RJ45
integrated switchYes
Protocols
MPINo
PROFINET IO ControllerYes
PROFINET IO DeviceNo
PROFINET CBAYes
PROFIBUS DP masterNo
PROFIBUS DP slaveNo
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Web serverYes
Point-to-point connectionNo
PROFINET IO Controller
Transmission rate, max.100 Mbit/s; full duplex
Services
— PG/OP communicationYes
— RoutingYes; With DP master module
— S7 communicationYes; with loadable FBs
— Isochronous modeNo
— Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
— IRTYes
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.32
— Number of connectable IO Devices, max.128
— Number of IO Devices with IRT and the option "high flexibility"128
— of which in line, max.61
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Activation/deactivation of IO DevicesYes
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Device replacement without swap mediumYes
— Send cyclesAdjustable: 250 µs, 500 µs and 1 ms
— Updating timeMinimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items.
— Updating times250 µs - 128 ms (with signal cycle 250 µs); 500 µs - 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms)
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
— User data consistency, max.254 byte; with PROFINET I/O
PROFINET CBA
acyclic transmissionYes
cyclic transmissionYes
Open IE communication
Number of connections, max.8
Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
2. Interface
Interface typeExternal interface via master module 6ES7138-4HA00-0AB0
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.No
Protocols
MPINo
PROFINET IO ControllerNo
PROFINET IO DeviceNo
PROFINET CBANo
PROFIBUS DP masterYes
PROFIBUS DP slaveNo
Open IE communicationNo
Web serverNo
Point-to-point connectionNo
PROFIBUS DP master
Number of connections, max.12; Notice: 12 connections per CPU, not per interface
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32; Per station
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeNo
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Number of DP slaves that can be simultaneously activated/deactivated, max.8
— Direct data exchange (slave-to-slave communication)Yes
— DPV1Yes
Address area
— Inputs, max.2 048 byte
— Outputs, max.2 048 byte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
Protocols
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length for connection type 01H, max.1 460 byte
— Data length for connection type 11H, max.8 192 byte
ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.8 192 byte
UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.1 472 byte
Web server
supportedYes
Number of HTTP clients5
Isochronous mode
Isochronous operation (application synchronized up to terminal)No
Communication functions
PG/OP communicationYes
Data record routingYes; With DP master module
Global data communication
supportedNo
S7 basic communication
supportedYes; I blocks
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte
S7 communication
supportedYes
as serverYes
as clientYes; via integrated PROFINET interface and loadable FBs
User data per job, max.180 byte
User data per job (of which consistent), max.64 byte
S5 compatible communication
supportedNo
Standard communication (FMS)
supportedNo
PROFINET CBA (at set setpoint communication load)
Setpoint for the CPU communication load50 %
Number of remote interconnection partners32
Number of functions, master/slave30
Total of all master/slave connections1 000
Data length of all incoming connections master/slave, max.4 000 byte
Data length of all outgoing connections master/slave, max.4 000 byte
Number of device-internal and PROFIBUS interconnections500
Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
Data length per connection, max.1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min.500 ms
— Number of incoming interconnections100
— Number of outgoing interconnections100
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
— Data length per connection, max.1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min.1 ms
— Number of incoming interconnections200
— Number of outgoing interconnections200
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
— Data length per connection, max.250 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
— HMI variable updating500 ms
— Number of HMI variables200
— Data length of all HMI variables, max.2 000 byte
PROFIBUS proxy functionality
— supportedYes
— Number of linked PROFIBUS devices16
— Data length per connection, max.240 byte; Slave-dependent
Number of connections
overall12
usable for PG communication11
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.11
usable for OP communication11
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.11
usable for S7 basic communication10
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.10
usable for S7 communication10; with loadable FBs
— adjustable for S7 communication, max.10
total number of instances, max.32
usable for routing4; With DP master module
S7 message functions
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ
simultaneously active Alarm-S blocks, max.300
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints2
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.500
— adjustableNo
— of which powerfail-proof100; Only the last 100 entries are retained
Interrupts/diagnostics/status information
AlarmsYes
Diagnostics functionYes
Diagnostics indication LED
for maintenanceYes; MT
Bus fault BF (red)Yes; BF-PN
Group error SF (red)Yes
Monitoring 24 V voltage supply ON (green)Yes
Bus activity PROFINET (green)Yes; P1-/P2-/P3-Link
Potential separation
between load voltage and all other switching componentsYes
between PROFIBUS DP and all other circuit componentsYes
Permissible potential difference
between different circuits75 V DC/60 V AC
Isolation
Isolation tested with500 V DC
Degree and class of protection
IP degree of protectionIP20
Configuration
Configuration software
STEP 7Yes; V5.4 SP4
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes; Optional
— CFCYes; Optional
— GRAPHYes; Optional
— HiGraph®Yes; Optional
Know-how protection
User program protection/password protectionYes
Cycle time monitoring
lower limit1 ms
upper limit6 000 ms
adjustableYes
preset150 ms
Dimensions
Width120 mm; DP master module: 35 mm
Height119.5 mm
Depth75 mm
Weights
Weight, approx.320 g; DP master module: Approx. 100 g
last modified:03/13/2019