| ***Spare part*** SIMATIC DP, Basic module ET 200X: BM 147-1 CPU, 64KB work memory for preliminary processing with int. SPS functionality, int. PROFIBUS-DP-Slave-SS, Degree of protection IP65/67, |
Supply voltage |
Load voltage 1L+ |
Rated value (DC) | 24 V; Permissible range: 20.4V to 28.8V |
Short-circuit protection | Yes |
Reverse polarity protection | No |
Load voltage 2L+ |
Rated value (DC) | 24 V; Permissible range: 20.4V to 28.8V |
Reverse polarity protection | No |
Input current |
from load voltage, unswitched (NS) |
up to 40 °C, max. | 10 A |
up to 55 °C, max. | 8 A |
from load voltage, switched (S) |
up to 40 °C, max. | 10 A |
up to 55 °C, max. | 8 A |
Power loss |
Power loss, typ. | 3 W |
Memory |
Work memory |
integrated | 64 kbyte; 21 K instructions |
expandable | No |
Load memory |
expandable FEPROM, max. | 8 Mbyte; can be plugged in as MMC |
Backup |
present | Yes; Guaranteed by MMC (maintenance-free) |
CPU processing times |
for bit operations, typ. | 0.1 µs |
for word operations, typ. | 0.2 µs |
for fixed point arithmetic, typ. | 2 µs |
for floating point arithmetic, typ. | 3 µs |
CPU-blocks |
Number of blocks (total) | 1 024; DBs, FCs, FBs |
DB |
Number, max. | 511 |
Size, max. | 16 kbyte |
FB |
Number, max. | 512; In number range from FB 0 to FB 2047 |
Size, max. | 16 kbyte |
FC |
Number, max. | 512; In number band of FC0 to FC2047 |
Size, max. | 16 kbyte |
OB |
Description | see instruction list |
Size, max. | 16 kbyte |
Nesting depth |
per priority class | 8 |
additional within an error OB | 4 |
Counters, timers and their retentivity |
S7 counter |
Number | 256 |
Retentivity |
— adjustable | Yes |
— preset | Z 0 to Z 7 |
Counting range |
— lower limit | 0 |
— upper limit | 999 |
IEC counter |
present | Yes; Number unlimited (limited only by work memory) |
Type | SFB |
S7 times |
Number | 256 |
Retentivity |
— adjustable | Yes |
— preset | No retentivity |
Time range |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer |
present | Yes; Number unlimited (limited only by work memory) |
Type | SFB |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | all |
Flag |
Number, max. | 256 byte |
Retentivity available | Yes |
Retentivity preset | MB 0 to MB 15 |
Number of clock memories | 8; 1 memory byte |
Local data |
per priority class, max. | 510 byte |
Address area |
I/O address area |
Inputs | 1 kbyte |
Outputs | 1 kbyte |
Process image |
Inputs | 128 byte |
Outputs | 128 byte |
Digital channels |
Inputs | 8 192 bit |
— of which central | 56 byte |
Outputs | 8 192 bit |
— of which central | 56 byte |
Analog channels |
Inputs | 512 words |
— of which central | 14 words |
Outputs | 512 words |
— of which central | 14 words |
Time of day |
Clock |
Hardware clock (real-time) | Yes |
retentive and synchronizable | Yes; Backup time typically 6 weeks (at 40 °C ambient temperature) |
Deviation per day, max. | 10 s |
Operating hours counter |
Number | 1 |
Number/Number range | 0 |
Range of values | 0 to 2^31 hours (when using SFC 101) |
Granularity | 1 h |
retentive | Yes; Must be restarted at each restart |
Clock synchronization |
supported | Yes |
to MPI, slave | Yes |
in AS, master | Yes |
in AS, slave | Yes |
1. Interface |
Interface type | Coexistent, integrated RS 485 interface |
Physics | RS 485 |
Isolated | Yes |
Protocols |
MPI | Yes |
PROFIBUS DP master | No |
PROFIBUS DP slave | Yes; active / passive |
Point-to-point connection | No |
MPI |
Transmission rate, max. | 12 Mbit/s |
Services |
— PG/OP communication | Yes |
— Routing | No |
— Global data communication | Yes |
— S7 basic communication | Yes |
— S7 communication | Yes |
— S7 communication, as server | Yes |
PROFIBUS DP slave |
Number of connections | 12 |
Transmission rate, max. | 12 Mbit/s |
Address area, max. | 32 |
User data per address area, max. | 32 byte |
Services |
— Routing | No |
— S7 communication, as client | No |
— S7 communication, as server | No |
Transfer memory |
— Inputs | 244 byte |
— Outputs | 244 byte |
Communication functions |
Global data communication |
Number of GD packets, max. | 4 |
Number of GD packets, transmitter, max. | 4 |
Number of GD packets, receiver, max. | 4 |
Size of GD packets, max. | 22 byte |
Size of GD packet (of which consistent), max. | 22 byte |
S7 basic communication |
User data per job, max. | 76 byte |
User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
as server | Yes |
as client | No |
User data per job, max. | 180 byte; With PUT/GET |
User data per job (of which consistent), max. | 64 byte |
S5 compatible communication |
supported | No |
Number of connections |
overall | 12 |
usable for PG communication | |
— reserved for PG communication | 1 |
— adjustable for PG communication, max. | 11 |
usable for OP communication | |
— reserved for OP communication | 1 |
— adjustable for OP communication, max. | 11 |
usable for S7 basic communication | |
— reserved for S7 basic communication | 10 |
— adjustable for S7 basic communication, max. | 11 |
S7 message functions |
Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes |
simultaneously active Alarm-S blocks, max. | 40 |
Test commissioning functions |
Status block | Yes |
Single step | Yes |
Number of breakpoints | 2 |
Status/control |
Status/control variable | Yes |
Variables | Inputs, outputs, memory bits, DB, times, counters |
Number of variables, max. | 30 |
— of which status variables, max. | 30 |
— of which control variables, max. | 14 |
Forcing |
Forcing | Yes |
Forcing, variables | Inputs, outputs |
Number of variables, max. | 10 |
Diagnostic buffer |
present | Yes |
Number of entries, max. | 100 |
— adjustable | No |
Potential separation |
between load voltage and all other switching components | Yes |
Configuration |
Configuration software |
STEP 7 | Yes; V5.2 SP1 |
Dimensions |
Width | 175 mm |
Height | 110 mm |
Depth | 90 mm |
Weights |
Weight, approx. | 700 g |
last modified: | 03/25/2019 |