6ES7147-1AA11-0XB0
ET200X, BM147/CPU, with SPS-Function

From SIEMENS

***Spare part*** SIMATIC DP, Basic module ET 200X: BM 147-1 CPU, 64KB work memory for preliminary processing with int. SPS functionality, int. PROFIBUS-DP-Slave-SS, Degree of protection IP65/67,
Supply voltage
Load voltage 1L+
Rated value (DC)24 V; Permissible range: 20.4V to 28.8V
Short-circuit protectionYes
Reverse polarity protectionNo
Load voltage 2L+
Rated value (DC)24 V; Permissible range: 20.4V to 28.8V
Reverse polarity protectionNo
Input current
from load voltage, unswitched (NS)
up to 40 °C, max.10 A
up to 55 °C, max.8 A
from load voltage, switched (S)
up to 40 °C, max.10 A
up to 55 °C, max.8 A
Power loss
Power loss, typ.3 W
Memory
Work memory
integrated64 kbyte; 21 K instructions
expandableNo
Load memory
expandable FEPROM, max.8 Mbyte; can be plugged in as MMC
Backup
presentYes; Guaranteed by MMC (maintenance-free)
CPU processing times
for bit operations, typ.0.1 µs
for word operations, typ.0.2 µs
for fixed point arithmetic, typ.2 µs
for floating point arithmetic, typ.3 µs
CPU-blocks
Number of blocks (total)1 024; DBs, FCs, FBs
DB
Number, max.511
Size, max.16 kbyte
FB
Number, max.512; In number range from FB 0 to FB 2047
Size, max.16 kbyte
FC
Number, max.512; In number band of FC0 to FC2047
Size, max.16 kbyte
OB
Descriptionsee instruction list
Size, max.16 kbyte
Nesting depth
per priority class8
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number256
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes; Number unlimited (limited only by work memory)
TypeSFB
S7 times
Number256
Retentivity
— adjustableYes
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes; Number unlimited (limited only by work memory)
TypeSFB
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.all
Flag
Number, max.256 byte
Retentivity availableYes
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Local data
per priority class, max.510 byte
Address area
I/O address area
Inputs1 kbyte
Outputs1 kbyte
Process image
Inputs128 byte
Outputs128 byte
Digital channels
Inputs8 192 bit
— of which central56 byte
Outputs8 192 bit
— of which central56 byte
Analog channels
Inputs512 words
— of which central14 words
Outputs512 words
— of which central14 words
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes; Backup time typically 6 weeks (at 40 °C ambient temperature)
Deviation per day, max.10 s
Operating hours counter
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, slaveYes
in AS, masterYes
in AS, slaveYes
1. Interface
Interface typeCoexistent, integrated RS 485 interface
PhysicsRS 485
IsolatedYes
Protocols
MPIYes
PROFIBUS DP masterNo
PROFIBUS DP slaveYes; active / passive
Point-to-point connectionNo
MPI
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingNo
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as serverYes
PROFIBUS DP slave
Number of connections12
Transmission rate, max.12 Mbit/s
Address area, max.32
User data per address area, max.32 byte
Services
— RoutingNo
— S7 communication, as clientNo
— S7 communication, as serverNo
Transfer memory
— Inputs244 byte
— Outputs244 byte
Communication functions
Global data communication
Number of GD packets, max.4
Number of GD packets, transmitter, max.4
Number of GD packets, receiver, max.4
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
as serverYes
as clientNo
User data per job, max.180 byte; With PUT/GET
User data per job (of which consistent), max.64 byte
S5 compatible communication
supportedNo
Number of connections
overall12
usable for PG communication
— reserved for PG communication1
— adjustable for PG communication, max.11
usable for OP communication
— reserved for OP communication1
— adjustable for OP communication, max.11
usable for S7 basic communication
— reserved for S7 basic communication10
— adjustable for S7 basic communication, max.11
S7 message functions
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.40
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints2
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.100
— adjustableNo
Potential separation
between load voltage and all other switching componentsYes
Configuration
Configuration software
STEP 7Yes; V5.2 SP1
Dimensions
Width175 mm
Height110 mm
Depth90 mm
Weights
Weight, approx.700 g
last modified:03/25/2019