6ES7134-0KH01-0XB0
ET200B, EL-MOD., 8AI, THERMO/PT100

From SIEMENS

*** SPARE PART*** SIMATIC DP, ELECTRONIC MODULE ANALOG, FOR ET 200B, W=160MM, 8AI (THERMOCOUPLES) OR 4AI (PT100); 12 BIT
General information
Usable terminal blockTB8
Supply voltage
Rated value (DC)24 V; Value at t < 0.5 s: 35 V
permissible range, lower limit (DC)18.5 V
permissible range, upper limit (DC)30.2 V
Input current
Current consumption, typ.80 mA; Logic
Power loss
Power loss, typ.2 W
Analog inputs
Number of analog inputs8; 8 voltage inputs/thermocouples or 4 Pt100, Ni100
permissible input voltage for voltage input (destruction limit), max.32 V
Input ranges
VoltageYes
ThermocoupleYes
Resistance thermometerYes
ResistanceYes
Input ranges (rated values), voltages
-1 V to +1 VYes
Input resistance (-1 V to +1 V)10 Ω
-250 mV to +250 mVYes
Input resistance (-250 mV to +250 mV)10 Ω
-500 mV to +500 mVYes
Input resistance (-500 mV to +500 mV)10 Ω
-80 mV to +80 mVYes
Input resistance (-80 mV to +80 mV)10 Ω
Input ranges (rated values), thermocouples
Type EYes
Type JYes
Type KYes
Type LYes
Type NYes
Type RYes
Type TYes
Type UYes
Input ranges (rated values), resistance thermometer
Ni 100Yes
Pt 100Yes
Input ranges (rated values), resistors
0 to 48 ohmsYes
0 to 150 ohmsYes
0 to 300 ohmsYes
0 to 600 ohmsYes
Characteristic linearization
parameterizableYes
— for thermocouplesType E, J, K, L, N, T, U
— for resistance thermometerPt100 (standard), Ni100 (standard)
Cable length
shielded, max.100 m
Analog value generation for the inputs
Measurement principleIntegrating voltage/time conversion
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.12 bit; Two's complement
Integration time, parameterizableYes; 2,5 / 16,67 / 20 / 100 ms
Basic conversion time, including integration time (ms)8 / 35 / 42 / 200
— additional conversion time for wire-break monitoring10 / 10 / 10 / 10 ms
Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10 Hz
Encoder
Connection of signal encoders
for voltage measurementYes
for resistance measurement with two-wire connectionYes
for resistance measurement with four-wire connectionYes
Errors/accuracies
Linearity error (relative to input range), (+/-)0.05 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, min.50 dB; At 50/60 Hz
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)1 %; At 80 mV; ±0.6 % from 250 to 1 000 mV
Resistance, relative to input range, (+/-)1 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.6 %; At 80 mV; ±0.4 % from 250 to 1 000 mV
Resistance, relative to input range, (+/-)0.6 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.40 dB
Common mode interference, min.70 dB; Upp < 3 V
Interfaces
PROFIBUS DP
Transmission rate, max.12 Mbit/s
Protocols
Bus protocol/transmission protocolPROFIBUS DP
Interrupts/diagnostics/status information
Alarms
Diagnostic alarmYes; Parameterizable
Limit value alarmYes; Parameterizable, channels 0 and 2
Diagnostic messages
OverrangeYes; Overrange
Wire-break in signal transmitter cableYes; For Pt 100, Ni 100, R, ±80 mV, thermocouples type E, J, K, L, N, T, U (parameterizable)
Diagnostics indication LED
RUN LEDYes
Bus fault BF (red)Yes
Potential separation
between electronic block and PROFIBUS DPYes
Potential separation analog inputs
Potential separation analog inputsNo
Permissible potential difference
between the inputs (UCM)max. ±1 V
Between the inputs and MANA (UCM)max. ±1 V
Degree and class of protection
Degree of protection acc. to EN 60529IP20
Ambient conditions
Ambient temperature during operation
horizontal installation, min.0 °C
horizontal installation, max.60 °C; 40°C for other mountings
Air pressure acc. to IEC 60068-2-13
permissible range, lower limit795 hPa
permissible range, upper limit1 080 hPa
Relative humidity
Operation, min.15 %
Operation, max.95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
Operation, tested according to IEC 60068-2-6Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)
Shock testing
tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms
Connection method
Design of electrical connection for the inputs and outputsScrew-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection
Dimensions
Width160 mm; EB and TB
Height130 mm; EB and TB
Depth60 mm; EB and TB
Weights
Weight, approx.550 g; EB and TB
last modified:03/13/2019