6ES7132-0BH11-0XB0
ET200B, EL-BLOCK, 16DO, DC 24V, 2A

From SIEMENS

*** SPARE PART*** SIMATIC DP, ELECTRONIC MODULE DIGITAL, FOR ET 200B, W=235MM, 16 DO 24V DC, 2A, DEGR. OF PROTECT. IP20,STANDARD
General information
Usable terminal blockTB2/DC, TB2-4/DC, TB4/DC, TB4-4/DC
Supply voltage
Rated value (DC)24 V; L1+, L2+, L3+, L4+, L5+; value at t < 0.5 s: 35 V
permissible range, lower limit (DC)18.5 V
permissible range, upper limit (DC)30.2 V
Input current
Current consumption, typ.100 mA; From L5+; logic
I²t0.05 A²·s; with starting current inrush
Power loss
Power loss, max.7 W
Digital outputs
Number of digital outputs16
Short-circuit protectionYes; Electronic
Limitation of inductive shutdown voltage totyp. (L1+ to L4+) -50 V
Controlling a digital inputYes
Switching capacity of the outputs
on lamp load, max.10 W
Output voltage
Rated value (DC)24 V
for signal "0", max.2 V; idling
for signal "1", min.UE -3 V
Output current
for signal "1" permissible range, max.2 A; in groups of 4
for signal "0" residual current, max.1 mA
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.0.5 Hz
on lamp load, max.8 Hz
Total current of the outputs (per group)
all mounting positions
— up to 60 °C, max.4 A
Cable length
unshielded, max.100 m
Interfaces
PROFIBUS DP
Transmission rate, max.12 Mbit/s
Protocols
Bus protocol/transmission protocolPROFIBUS DP
PROFIBUS DP
Services
— SYNC capabilityYes
Interrupts/diagnostics/status information
Diagnostics indication LED
RUN LEDYes
Bus fault BF (red)Yes
Status indicator digital output (green)Yes
Potential separation
between electronic block and PROFIBUS DPYes
Potential separation digital outputs
Potential separation digital outputsYes
between the channels, in groups of4
Degree and class of protection
Degree of protection acc. to EN 60529IP20
Ambient conditions
Ambient temperature during operation
horizontal installation, min.0 °C
horizontal installation, max.60 °C; 40°C for other mountings
Air pressure acc. to IEC 60068-2-13
permissible range, lower limit795 hPa
permissible range, upper limit1 080 hPa
Relative humidity
Operation, min.15 %
Operation, max.95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
Operation, tested according to IEC 60068-2-6Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)
Shock testing
tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms
Connection method
Design of electrical connection for the inputs and outputsScrew-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection
Dimensions
Width235 mm; EB and TB
Height130 mm; EB and TB
Depth60 mm; EB and TB
Weights
Weight, approx.900 g; EB and TB
last modified:03/13/2019