6DL1133-6EW00-0PH1
ET 200SP HA, AI-DI16/DQ16X24VDC HART

From SIEMENS

SIMATIC ET 200SP HA, configurable I/O module, AI-DI16/DQ16X24VDC HART, suitable for terminal block H1, M1, color code CC00, channel diagnostics, 16-bit, +/-0.1%,
General information
Product type designationAI-DI 16/DQ 16x24VDC HART HA
Firmware versionV1.0
FW update possibleYes
Usable terminal blockTB type H1, M1 and N0
Color code for module-specific color identification plateCC00
Product function
I&M dataYes; I&M0 to I&M3
Engineering with
PCS 7 configurable/integrated as of versionV9.0
Operating mode
DIYes
CounterNo
DQYes
DQ with energy-saving functionNo
PWMNo
OversamplingNo
MSINo
MSONo
Redundancy
Redundancy capabilityYes; With TB type M1
CiR – Configuration in RUN
Reparameterization possible in RUNYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption (rated value)80 mA; without sensor supply
Current consumption, max.90 mA; without sensor supply
Encoder supply
Number of outputs16
Output voltage encoder supply, min.18.2 V
Short-circuit protectionYes; per channel, electronic
24 V encoder supply
24 VYes
Short-circuit protectionYes; Electronic (response threshold 0.7 A to 1.5 A)
Output current per channel, max.0.5 A
Output current per module, max.2 A
Power loss
Power loss, typ.4.5 W; without sensor supply
Address area
Address space per module
Address space per module, max.42 byte; Address space per module (analog): 42 bytes. Of which 34 bytes for outputs, 2 bytes for outputs and 6 bytes for QI information. Address space per module (digital): 26 bytes. Of which 2 bytes for inputs, 2 bytes for outputs, 18 bytes for SoE, and 4 bytes for QI information
Address space per module with HART, max.82 byte; 34-byte inputs, 2-byte outputs, 40 bytes for HART secondary variables, and 6 bytes for QI information
Address space per module with MultiHART, max.70 byte; 34-byte inputs, 2-byte outputs, 24-byte HART inputs, 4-byte HART outputs, and 6 bytes for QI information
Digital inputs
Number of digital inputs16
Digital inputs, parameterizableYes
Source/sink inputYes; P-reading
Input characteristic curve in accordance with IEC 61131, type 1Yes
Input characteristic curve in accordance with IEC 61131, type 2No
Input characteristic curve in accordance with IEC 61131, type 3Yes
Pulse extensionYes; Off, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s
Time stampingYes; Resolution 10 ms
Time stamp (with precision of 1 ms)Yes; Resolution 1ms
Edge evaluationYes; rising edge, falling edge, edge change
Input voltage
Type of input voltageDC
Rated value (DC)24 V
for signal "0"-30 to +5V
for signal "1"+11 to +30V
Input current
for signal "1", typ.2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizableYes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of 30 to 500 µs, depending on line length)
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Digital outputs
Number of digital outputs16
Current-sinkingNo
Current-sourcingYes
Short-circuit protectionYes; Response threshold 0.7 A to 1.3 A
Open-circuit detectionYes
Overload protectionYes
Limitation of inductive shutdown voltage toL+ -(37 to 41V)
Controlling a digital inputYes
Switching capacity of the outputs
with resistive load, max.0.5 A
on lamp load, max.5 W
Load resistance range
lower limit48 Ω
upper limit12 kΩ
Output current
for signal "1" rated value0.5 A
for signal "0" residual current, max.0.7 mA
Output delay with resistive load
"0" to "1", typ.50 µs
"1" to "0", typ.100 µs
Parallel switching of two outputs
for upratingNo
for redundant control of a loadYes
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.2 Hz
on lamp load, max.10 Hz
Total current of the outputs
Current per channel, max.0.5 A
Current per module, max.2 A
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Analog inputs
Number of analog inputs16
permissible input current for current input (destruction limit), max.30 mA
Input ranges (rated values), currents
0 to 20 mAYes; 16 bit incl. sign
Input resistance (0 to 20 mA)250 Ω
4 mA to 20 mAYes; 16 bit incl. sign
Input resistance (4 mA to 20 mA)250 Ω
Analog value generation for the inputs
Measurement principleintegrating (Sigma-Delta)
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.16 bit; 15 bit at 0 ... 10 mA and 60 Hz interference suppression
Integration time, parameterizableYes; channel by channel
Smoothing of measured values
parameterizableYes; none, weak, medium, strong, channel-by-channel
Encoder
Connection of signal encoders
for current measurement as 2-wire transducerYes
Connectable encoders
2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Errors/accuracies
Linearity error (relative to input range), (+/-)0.01 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, min.60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Operational error limit in overall temperature range
Current, relative to input range, (+/-)0.5 %
Basic error limit (operational limit at 25 °C)
Current, relative to input range, (+/-)0.1 %
Interrupts/diagnostics/status information
Diagnostics functionYes
Substitute values connectableYes
Alarms
Diagnostic alarmYes
Limit value alarmYes; two upper and two lower limit values in each case
Diagnostic messages
Monitoring the supply voltageYes
Wire-breakYes; channel by channel
Short-circuit to MYes; Encoder supply to M, channel by channel
Group errorYes
Overflow/underflowYes; channel by channel
Diagnostics indication LED
MAINT LEDYes; yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayNo
for channel diagnosticsNo
for module diagnosticsYes; green/red DIAG LED
Potential separation
Potential separation channels
between the channelsNo
between the channels and backplane busYes
Between the channels and load voltage L+No
Isolation
Isolation tested with1 500 V DC/1 min, type test
Ambient conditions
Ambient temperature during operation
horizontal installation, min.-40 °C
horizontal installation, max.70 °C; Observe derating
vertical installation, min.-40 °C
vertical installation, max.60 °C; Observe derating
Dimensions
Width22.5 mm
Height115 mm
Depth138 mm
Weights
Weight, approx.150 g
last modified:03/02/2019