6AV7241-.....-....
SIMATIC IPC 477E

From SIEMENS

SIMATIC IPC 477E computing unit, 4 USB (back), Ethernet (10/100/1000);
Installation type/mounting
DesignPanel PC, built-in unit
Supply voltage
Type of supply voltage100/240 V AC (autorange) 50/60 Hz; optional 24 V DC
Line frequency
Rated value 50 HzYes
Rated value 60 HzYes
Mains buffering
Mains/voltage failure stored energy time20 ms
Processor
Processor typeCeleron G3902 (2C/2T, 1.6 GHz, 2 MB Cache); Core i3-6102E (2C/4T, 1.9 GHz, 3 MB Cache); Core i5-6442EQ (4C/4T, 1.9 (2.7) GHz, 6 MB Cache, iAMT); Xeon E3-1505L v5 (4C/8T, 2.0 (2.8) GHz, 8 MB Cache, iAMT)
Graphic
Graphics controllerIntel HD graphics controller
Drives
Optical drivespossible as external drive via USB
Hard disk2.5" SATA hard disk, at least 320 GB
SSDYes; 1x 128 GB, 1x 240 GB SSD, 1x 480 GB SSD
Memory
Type of memoryDDR4 SO-DIMM
Main memory4 GB to 16 GB, ECC optional
Capacity of main memory, max.16 Gbyte
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; 128 KB can be stored in the buffer time; optional
Hardware configuration
Slots
free slots1x PCIe (slot with card retainer), 1x slot for CFAST card
Number of PCI slots1; Optional
Number of compact flash slots1; CFast
Interfaces
Number of industrial Ethernet interfaces3; 3x Ethernet (RJ45)
USB port4x USB 3.0
Connection for keyboard/mouseUSB / USB
serial interfaceWithout / 2x COM (RS 232 / 422 / 485), selectable in the BIOS
Video interfaces
Graphics interface2x DisplayPort
Industrial Ethernet
Industrial Ethernet interface3x Ethernet (RJ45)
— 100 MbpsYes
— 1000 MbpsYes
Interrupts/diagnostics/status information
Bus diagnosticsYes
Integrated Functions
Monitoring functions
Temperature monitoringYes
WatchdogYes
FanNo
Monitoring function via networkOptional
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2
Interference immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation10 V/m, 80 ... 2 000 MHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 ... 2.7 GHz; 10 V, 10 kHz ... 80 MHz acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
Interference immunity on supply cables±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric
Interference immunity on signal cables >30m±2 kV acc. to IEC 61000-4-5, surge, length > 30 m
Interference immunity on signal cables < 30m±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m
Interference immunity against voltage surge
asymmetric interference±2 kV acc. to IEC 61000-4-5, surge asymmetric
symmetric interference±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
Interference immunity to magnetic fields at 50 Hz100 A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
Interference emission via line/AC current cablesEN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A
Degree and class of protection
IP (at the front)IP65
IP (rear)IP20
Standards, approvals, certificates
CE markYes; CE marking / EC Declaration of Conformity
CSA approvalYes
UL approvalYes
UL 508Yes
cULusYes
RCM (formerly C-TICK)Yes
KC approvalYes
FCCYes
EMCCE, EN 61000-6-4; CISPR 22:2004 Class A; FCC Class A
Use in hazardous areas
ATEX Zone 2Yes; Optional, only with Multitouch
IECEx Zone 2Yes; Optional, only with Multitouch
cULus Class I Zone 2, Division 2Yes; Optional, only with Multitouch
Marine approval
Germanischer Lloyd (GL)Yes
American Bureau of Shipping (ABS)Yes
Bureau Veritas (BV)Yes
Det Norske Veritas (DNV)Yes
Korean Register of Shipping (KRS)Yes
Lloyds Register of Shipping (LRS)Yes
Nippon Kaiji Kyokai (Class NK)Yes
Ambient conditions
Ambient temperature during operation
Ambient temperature during operation0 to +45°C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-6IEC 60068-2-6; 5 Hz to 9 Hz: 3.5 mm; 9 Hz to 500 Hz: 9.8 m/s² (with SSD or CFast); 10 Hz to 58 Hz: 0.0375 mm; 58 Hz to 200 Hz: 4.9 m/s² (hard disk)
Shock testing
Shock load during operationIEC 60068-2-27; 150 m/s², 11 ms (without hard disk); 50 m/s², 30 ms (with hard disk)
Operating systems
pre-installed operating systemWindows 7 Ultimate (Multi-Language) 64-bit, Windows Embedded Standard 7 E/P 32-bit / 64-bit, Windows 10
without operating systemYes; Optional
pre-installed operating system
Windows 7Yes; Ultimate 64 bit
Windows 10 EnterpriseYes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI
last modified:02/22/2020

External links