6AV6671-5AE00-0AX0 Connect. Box DP Basic for Mobile Panel
From SIEMENS
Connection box DP Basic for Mobile Panels (MPI/PROFIBUS) | ||
General information | ||
Product function | ||
Location identifier | Yes | |
FH technology | ||
Safety evaluation through direct wiring | ||
Reconnection with emergency stop circuit interruption | Yes | |
Monitoring the STOP button | No | |
Supply voltage | ||
Type of supply voltage | 24 V DC | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Input current | ||
Current consumption (rated value) | 0.4 A | |
Power | ||
Active power input, typ. | 10 W | |
Interfaces | ||
Interfaces/bus type | 1x RS 232, 1x RS 422, 1x RS 485 (max. 12 Mbit/s) | |
Number of RS 485 interfaces | 1 | |
Number of RS 422 interfaces | 1 | |
Number of RS 232 interfaces | 1 | |
Number of 20 mA interfaces (TTY) | 0 | |
Connection point identification | Yes | |
Degree and class of protection | ||
Degree of protection acc. to EN 60529 | IP65 | |
Standards, approvals, certificates | ||
CE mark | Yes | |
CSA approval | No | |
UL approval | No | |
cULus | Yes | |
RCM (formerly C-TICK) | Yes | |
EAC (formerly Gost-R) | No | |
Marine approval | No | |
Use in hazardous areas | ||
ATEX Zone 2 | No | |
ATEX Zone 22 | No | |
FM Class I Division 2 | No | |
Ambient conditions | ||
Ambient temperature during operation | ||
Operation (vertical installation) | 0 to +50 °C | |
— For vertical installation, min. | 0 °C | |
— For vertical installation, max. | 50 °C | |
Ambient temperature during storage/transportation | ||
min. | -20 °C | |
max. | 70 °C | |
Relative humidity | ||
Operation, max. | 85 % | |
Dimensions | ||
Width | 160 mm | |
Height | 120 mm | |
Depth | 70 mm | |
Weights | ||
Weight (without packaging) | 0.35 kg | |
Other | ||
free hotline | Yes | |
Usable in the following products | ||
Product 1 | 6AV6645-0A* | |
Product 2 | 6AV6645-0C* | |
Product 3 | ||
last modified: | 03/13/2019 |