| SIMATIC IPC427D (Microbox PC), HD graphic onboard, 2x10/100/1000 Mbit/s Ethernet RJ45, 4xUSB V3.0 (high current), PCIe (optional), 24 V DC power supply |
General information |
Product type designation | IPC427D |
Installation type/mounting |
Mounting | DIN rail, wall mounting, portrait mounting |
Design | Box PC, built-in unit |
Supply voltage |
Type of supply voltage | 24 V DC |
Processor |
Processor type | Celeron 827E (1C/1T, 1.40 GHz, 1.5 MB Cache); Core i3-3217UE (2C/4T, 1.60 GHz, 3 MB Cache); Core i7-3517UE (2C/4T, 1.70 (2.80) GHz, 4 MB Cache, iAMT) |
Graphic |
Graphics controller | Intel HD Graphics, Intel HD Graphics 4000 |
Drives |
Hard disk | 2.5" SATA ≥ 320 GB |
SSD | Yes; 1x 240 GB SSD, 1x 480 GB SSD |
Memory |
Type of memory | DDR3 SO-DIMM |
Main memory | 2 / 4 / 8 GB; ECC optional |
Capacity of main memory, max. | 8 Gbyte |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; 128 KB can be stored in the buffer time; optional |
Hardware configuration |
Slots |
free slots | 2x PCIe; optional: 1x PCIe (x4); 2x PCIe (x1, x4), with card retainer |
Number of PCI slots | 2; Optional |
Number of compact flash slots | 2; CFast |
Interfaces |
PROFIBUS/MPI | Optionally onboard, isolated, max. 12 Mbps, compatible with CP 5611 |
Number of PROFINET interfaces | 1; 3 ports (incl. switch) |
USB port | 4x USB 3.0 |
Connection for keyboard/mouse | USB / USB |
serial interface | COM1: 1x RS 232, COM2 (optional): 1x RS 232 |
Video interfaces |
Graphics interface | 1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional) |
Industrial Ethernet |
Industrial Ethernet interface | Onboard, 2x 10/100/1 000 Mbit, RJ45, no plug-in card necessary |
— 100 Mbps | Yes |
— 1000 Mbps | Yes |
Interrupts/diagnostics/status information |
Bus diagnostics | Yes |
Integrated Functions |
Monitoring functions |
Temperature monitoring | Yes |
Watchdog | Yes |
Status LEDs | Yes |
Fan | No |
Monitoring function via network | Optional |
EMC |
Interference immunity against discharge of static electricity |
Interference immunity against discharge of static electricity | ±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2 |
Interference immunity against high-frequency electromagnetic fields |
Interference immunity against high frequency radiation | 10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6 |
Interference immunity to cable-borne interference |
Interference immunity on supply cables | ±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric |
Interference immunity on signal cables >30m | ±2 kV acc. to IEC 61000-4-5, surge, length > 30 m |
Interference immunity on signal cables < 30m | ±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m |
Interference immunity against voltage surge |
asymmetric interference | ±2 kV acc. to IEC 61000-4-5, surge asymmetric |
symmetric interference | ±1 kV acc. to IEC 61000-4-5, surge symmetric |
Interference immunity to magnetic fields |
Interference immunity to magnetic fields at 50 Hz | 100 A/m; to IEC 61000-4-8 |
Emission of conducted and non-conducted interference |
Interference emission via line/AC current cables | EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A |
Degree and class of protection |
IP (at the front) | IP20 |
IP (rear) | IP20 |
Standards, approvals, certificates |
CE mark | Yes; CE marking / EC Declaration of Conformity |
UL approval | Yes |
UL 508 | Yes |
cULus | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
FCC | Yes |
EMC | CE, EN 55022A, EN 61000-6-4, EN 61000-6-2 |
Use in hazardous areas |
ATEX Zone 2 | Yes |
IECEx Zone 2 | Yes |
cULus Class I Zone 2, Division 2 | Yes |
Marine approval |
Germanischer Lloyd (GL) | Yes |
American Bureau of Shipping (ABS) | Yes |
Bureau Veritas (BV) | Yes |
Det Norske Veritas (DNV) | Yes |
Korean Register of Shipping (KRS) | Yes |
Lloyds Register of Shipping (LRS) | Yes |
Nippon Kaiji Kyokai (Class NK) | Yes |
Ambient conditions |
Ambient temperature during operation |
Ambient temperature during operation | 0 °C to +55 °C |
Ambient temperature during storage/transportation |
min. | -40 °C |
max. | 70 °C |
Relative humidity |
Relative humidity | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5% to 80% at 25 °C (no condensation), Storage: 5% to 95% at 25 °C (no condensation) |
Vibrations |
Vibration resistance during operation acc. to IEC 60068-2-6 | Tested to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm, 58 Hz to 200 Hz: 9.8 m/s² (1 g) |
Shock testing |
Shock load during operation | Tested to DIN IEC 60068-2-29: 50 m/s² (5 g), 30 ms, 100 shocks |
Operating systems |
Operating system | Windows 7 Ultimate (Multi-Language) 32-bit / 64-bit, Windows Embedded Standard 7 E/P 32-bit / 64-bit |
pre-installed operating system | Yes |
without operating system | Yes; Optional |
pre-installed operating system |
Windows 7 | Yes; Ultimate 32 bit or 64 bit |
Software |
SIMATIC Software | Optionally with pre-installed software bundle SIMATIC WinCC RT Advanced / WinAC RTX |
Dimensions |
Width | 262 mm |
Height | 139.7 mm |
Depth | 50.5 mm |
last modified: | 03/13/2019 |