6AG1412-3HJ14-4AB0
SIPLUS _CPU 412-3H

From SIEMENS

***Spare part*** SIPLUS S7-400 CPU 412-3H for medial exposure with conformal coating based on 6ES7412-3HJ14-0AB0 . not permitted for safety-oriented applications!
General information
Product type designationCPU 412-3H
HW functional status1
Firmware versionV4.5
Engineering with
Programming packageSTEP 7 V5.3 SP2 or higher with HW update
CiR – Configuration in RUN
CiR synchronization time, basic load150 ms
CiR synchronization time, time per I/O byte40 µs
Supply voltage
Rated value (DC)
24 V DCNo; Power supply via system power supply
Input current
from backplane bus 5 V DC, typ.1.2 A
from backplane bus 5 V DC, max.1.5 A
from backplane bus 24 V DC, max.150 mA; Per DP interface
from interface 5 V DC, max.90 mA; At each DP interface
Power loss
Power loss, typ.5.5 W
Memory
Type of memoryother
Work memory
integrated768 kbyte
integrated (for program)512 kbyte
integrated (for data)256 kbyte
expandableNo
Load memory
expandable FEPROMYes
expandable FEPROM, max.64 Mbyte
integrated RAM, max.256 kbyte
expandable RAMYes
expandable RAM, max.64 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
Battery
Backup battery
Backup current, typ.190 µA; Valid up to 40°C
Backup current, max.660 µA
Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times
for bit operations, typ.0.075 µs
for word operations, typ.0.075 µs
for fixed point arithmetic, typ.0.075 µs
for floating point arithmetic, typ.0.225 µs
CPU-blocks
DB
Number, max.4 095; Number range: 1 to 4095
Size, max.64 kbyte
FB
Number, max.2 048; Number range: 0 to 2047
Size, max.64 kbyte
FC
Number, max.2 048; Number range: 0 to 2047
Size, max.64 kbyte
OB
Size, max.64 kbyte
Number of time alarm OBs4
Number of delay alarm OBs4
Number of cyclic interrupt OBs4
Number of process alarm OBs4
Nesting depth
per priority class24
additional within an error OB1
Counters, timers and their retentivity
S7 counter
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
S7 times
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetNo times retentive
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
Data areas and their retentivity
retentive data area in totalTotal working and load memory (with backup battery)
Flag
Number, max.8 kbyte
Retentivity availableYes
Retentivity presetMB 0 to MB 15
Number of clock memories8; in 1 memory byte
Local data
adjustable, max.16 kbyte
preset8 kbyte
Address area
I/O address area
Inputs8 kbyte
Outputs8 kbyte
Process image
Inputs, adjustable8 kbyte
Outputs, adjustable8 kbyte
Inputs, default256 byte
Outputs, default256 byte
consistent data, max.244 byte
Access to consistent data in process imageYes
Subprocess images
Number of subprocess images, max.15
Digital channels
Inputs65 536
— of which central65 536
Outputs65 536
— of which central65 536
Analog channels
Inputs4 096
— of which central4 096
Outputs4 096
— of which central4 096
Hardware configuration
Number of expansion units, max.21
connectable OPs15 without message processing, 8 with message processing
MulticomputingNo
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.4; Single mode only
Number of DP masters
integrated1
via CP10
Mixed mode IM + CP permittedNo
via interface module0
Number of operable FMs and CPs (recommended)
FMSee manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
CP, PtPSee manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
PROFIBUS and Ethernet CPs14; Of which max. 10 CP as DP master
Slots
required slots2
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Resolution1 ms
Deviation per day (buffered), max.1.7 ms; Power off
Deviation per day (unbuffered), max.8.6 ms; Power on
Operating hours counter
Number8
Number/Number range0 to 7
Range of values0 to 32767 hours
Granularity1 h
retentiveYes
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
Time difference in system when synchronizing via
MPI, max.200 ms
Interfaces
Number of RS 485 interfaces2
Number of other interfaces0
1. Interface
Interface typeIntegrated
PhysicsRS 485 / PROFIBUS + MPI
IsolatedYes
Power supply to interface (15 to 30 V DC), max.150 mA
Number of connection resourcesMPI: 16, DP: 16
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP slaveNo
MPI
Number of connections16
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
PROFIBUS DP master
Number of connections, max.16
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— EquidistanceNo
— SYNC/FREEZENo
— Activation/deactivation of DP slavesNo
— Direct data exchange (slave-to-slave communication)No
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP slave
— User data per DP slave, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP slave
Number of connectionsNo configuration of CPU as DP slave
3. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization submodule IF 960 6ES7 960-1AA04-0XA0
4. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization submodule IF 960 6ES7 960-1AA04-0XA0
Isochronous mode
Isochronous operation (application synchronized up to terminal)No
EquidistanceNo
Communication functions
PG/OP communicationYes
Number of connectable OPs without message processing15
Number of connectable OPs with message processing8
Global data communication
supportedNo
S7 basic communication
supportedNo
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 kbyte
User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication
supportedYes; (via CP max. 10 and FC AG_SEND and FC AG_RECV)
User data per job, max.8 kbyte
User data per job (of which consistent), max.240 byte
Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
Standard communication (FMS)
supportedYes; Via CP and loadable FB
Number of connections
overall16
usable for PG communication
— reserved for PG communication1
— adjustable for PG communication, max.0
usable for OP communication
— reserved for OP communication1
— adjustable for OP communication, max.0
usable for S7 basic communication
— reserved for S7 basic communication0
— adjustable for S7 basic communication, max.0
usable for S7 communication
— reserved for S7 communication0
— adjustable for S7 communication, max.0
usable for routing
— reserved for routing0
— adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.8
Symbol-related messagesNo
Program alarmsYes
simultaneously active Alarm-S blocks, max.100
Alarm 8-blocksYes
Number of instances for alarm 8 and S7 communication blocks, max.600
preset, max.300
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)16
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.70
Forcing
ForcingYes
Forcing, variablesInputs/outputs, bit memories, distributed I/Os
Number of variables, max.256
Diagnostic buffer
presentYes
Number of entries, max.3 200
— adjustableYes
— preset120
Standards, approvals, certificates
CE markYes
Ambient conditions
Ambient temperature during operation
min.0 °C; = Tmin
max.60 °C; = Tmax
Altitude during operation relating to sea level
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Configuration
Configuration software
STEP 7Yes
Programming
Command setsee instruction list
Nesting levels8
Access to consistent data in process imageYes
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Number of simultaneously active SFCs
— RD_REC8
— WR_REC8
— WR_PARM8
— PARM_MOD1
— WR_DPARM2
— DPNRM_DG8
— RDSYSST8
— DP_TOPOL1
Number of simultaneously active SFBs
— RDREC8
— WRREC8
Know-how protection
User program protection/password protectionYes
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.990 g
last modified:03/13/2019