| ***Spare part*** SIPLUS S7-400 CPU 412-3H for medial exposure with conformal coating based on 6ES7412-3HJ14-0AB0 . not permitted for safety-oriented applications! |
General information |
Product type designation | CPU 412-3H |
HW functional status | 1 |
Firmware version | V4.5 |
Engineering with |
Programming package | STEP 7 V5.3 SP2 or higher with HW update |
CiR – Configuration in RUN |
CiR synchronization time, basic load | 150 ms |
CiR synchronization time, time per I/O byte | 40 µs |
Supply voltage |
Rated value (DC) | |
24 V DC | No; Power supply via system power supply |
Input current |
from backplane bus 5 V DC, typ. | 1.2 A |
from backplane bus 5 V DC, max. | 1.5 A |
from backplane bus 24 V DC, max. | 150 mA; Per DP interface |
from interface 5 V DC, max. | 90 mA; At each DP interface |
Power loss |
Power loss, typ. | 5.5 W |
Memory |
Type of memory | other |
Work memory |
integrated | 768 kbyte |
integrated (for program) | 512 kbyte |
integrated (for data) | 256 kbyte |
expandable | No |
Load memory |
expandable FEPROM | Yes |
expandable FEPROM, max. | 64 Mbyte |
integrated RAM, max. | 256 kbyte |
expandable RAM | Yes |
expandable RAM, max. | 64 Mbyte |
Backup |
present | Yes |
with battery | Yes; all data |
without battery | No |
Battery |
Backup battery |
Backup current, typ. | 190 µA; Valid up to 40°C |
Backup current, max. | 660 µA |
Backup time, max. | Dealt with in the module data manual with the secondary conditions and the factors of influence |
Feeding of external backup voltage to CPU | 5 V DC to 15 V DC |
CPU processing times |
for bit operations, typ. | 0.075 µs |
for word operations, typ. | 0.075 µs |
for fixed point arithmetic, typ. | 0.075 µs |
for floating point arithmetic, typ. | 0.225 µs |
CPU-blocks |
DB |
Number, max. | 4 095; Number range: 1 to 4095 |
Size, max. | 64 kbyte |
FB |
Number, max. | 2 048; Number range: 0 to 2047 |
Size, max. | 64 kbyte |
FC |
Number, max. | 2 048; Number range: 0 to 2047 |
Size, max. | 64 kbyte |
OB |
Size, max. | 64 kbyte |
Number of time alarm OBs | 4 |
Number of delay alarm OBs | 4 |
Number of cyclic interrupt OBs | 4 |
Number of process alarm OBs | 4 |
Nesting depth |
per priority class | 24 |
additional within an error OB | 1 |
Counters, timers and their retentivity |
S7 counter |
Number | 2 048 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | Z 0 to Z 7 |
Counting range |
— lower limit | 0 |
— upper limit | 999 |
IEC counter |
present | Yes |
Type | SFB |
S7 times |
Number | 2 048 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | No times retentive |
Time range |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer |
present | Yes |
Type | SFB |
Data areas and their retentivity |
retentive data area in total | Total working and load memory (with backup battery) |
Flag |
Number, max. | 8 kbyte |
Retentivity available | Yes |
Retentivity preset | MB 0 to MB 15 |
Number of clock memories | 8; in 1 memory byte |
Local data |
adjustable, max. | 16 kbyte |
preset | 8 kbyte |
Address area |
I/O address area |
Inputs | 8 kbyte |
Outputs | 8 kbyte |
Process image |
Inputs, adjustable | 8 kbyte |
Outputs, adjustable | 8 kbyte |
Inputs, default | 256 byte |
Outputs, default | 256 byte |
consistent data, max. | 244 byte |
Access to consistent data in process image | Yes |
Subprocess images |
Number of subprocess images, max. | 15 |
Digital channels |
Inputs | 65 536 |
— of which central | 65 536 |
Outputs | 65 536 |
— of which central | 65 536 |
Analog channels |
Inputs | 4 096 |
— of which central | 4 096 |
Outputs | 4 096 |
— of which central | 4 096 |
Hardware configuration |
Number of expansion units, max. | 21 |
connectable OPs | 15 without message processing, 8 with message processing |
Multicomputing | No |
Interface modules |
Number of connectable IMs (total), max. | 6 |
Number of connectable IM 460s, max. | 6 |
Number of connectable IM 463s, max. | 4; Single mode only |
Number of DP masters |
integrated | 1 |
via CP | 10 |
Mixed mode IM + CP permitted | No |
via interface module | 0 |
Number of operable FMs and CPs (recommended) |
FM | See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections |
CP, PtP | See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections |
PROFIBUS and Ethernet CPs | 14; Of which max. 10 CP as DP master |
Slots |
required slots | 2 |
Time of day |
Clock |
Hardware clock (real-time) | Yes |
retentive and synchronizable | Yes |
Resolution | 1 ms |
Deviation per day (buffered), max. | 1.7 ms; Power off |
Deviation per day (unbuffered), max. | 8.6 ms; Power on |
Operating hours counter |
Number | 8 |
Number/Number range | 0 to 7 |
Range of values | 0 to 32767 hours |
Granularity | 1 h |
retentive | Yes |
Clock synchronization |
supported | Yes |
to MPI, master | Yes |
to MPI, slave | Yes |
to DP, master | Yes |
to DP, slave | Yes |
in AS, master | Yes |
in AS, slave | Yes |
Time difference in system when synchronizing via |
MPI, max. | 200 ms |
Interfaces |
Number of RS 485 interfaces | 2 |
Number of other interfaces | 0 |
1. Interface |
Interface type | Integrated |
Physics | RS 485 / PROFIBUS + MPI |
Isolated | Yes |
Power supply to interface (15 to 30 V DC), max. | 150 mA |
Number of connection resources | MPI: 16, DP: 16 |
Protocols |
MPI | Yes |
PROFIBUS DP master | Yes |
PROFIBUS DP slave | No |
MPI |
Number of connections | 16 |
Transmission rate, max. | 12 Mbit/s |
Services |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
PROFIBUS DP master |
Number of connections, max. | 16 |
Transmission rate, max. | 12 Mbit/s |
Number of DP slaves, max. | 32 |
Services |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— Equidistance | No |
— SYNC/FREEZE | No |
— Activation/deactivation of DP slaves | No |
— Direct data exchange (slave-to-slave communication) | No |
Address area |
— Inputs, max. | 2 kbyte |
— Outputs, max. | 2 kbyte |
User data per DP slave |
— User data per DP slave, max. | 244 byte |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
— Slots, max. | 244 |
— per slot, max. | 128 byte |
PROFIBUS DP slave |
Number of connections | No configuration of CPU as DP slave |
3. Interface |
Interface type | Pluggable synchronization submodule (FO) |
Plug-in interface modules | Synchronization submodule IF 960 6ES7 960-1AA04-0XA0 |
4. Interface |
Interface type | Pluggable synchronization submodule (FO) |
Plug-in interface modules | Synchronization submodule IF 960 6ES7 960-1AA04-0XA0 |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) | No |
Equidistance | No |
Communication functions |
PG/OP communication | Yes |
Number of connectable OPs without message processing | 15 |
Number of connectable OPs with message processing | 8 |
Global data communication |
supported | No |
S7 basic communication |
supported | No |
S7 communication |
supported | Yes |
as server | Yes |
as client | Yes |
User data per job, max. | 64 kbyte |
User data per job (of which consistent), max. | 462 byte; 1 variable |
S5 compatible communication |
supported | Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV) |
User data per job, max. | 8 kbyte |
User data per job (of which consistent), max. | 240 byte |
Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 24/24 |
Standard communication (FMS) |
supported | Yes; Via CP and loadable FB |
Number of connections |
overall | 16 |
usable for PG communication | |
— reserved for PG communication | 1 |
— adjustable for PG communication, max. | 0 |
usable for OP communication | |
— reserved for OP communication | 1 |
— adjustable for OP communication, max. | 0 |
usable for S7 basic communication | |
— reserved for S7 basic communication | 0 |
— adjustable for S7 basic communication, max. | 0 |
usable for S7 communication | |
— reserved for S7 communication | 0 |
— adjustable for S7 communication, max. | 0 |
usable for routing | |
— reserved for routing | 0 |
— adjustable for routing, max. | 0 |
S7 message functions |
Number of login stations for message functions, max. | 8 |
Symbol-related messages | No |
Program alarms | Yes |
simultaneously active Alarm-S blocks, max. | 100 |
Alarm 8-blocks | Yes |
Number of instances for alarm 8 and S7 communication blocks, max. | 600 |
preset, max. | 300 |
Process control messages | Yes |
Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 16 |
Test commissioning functions |
Status block | Yes |
Single step | Yes |
Number of breakpoints | 4 |
Status/control |
Status/control variable | Yes |
Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Number of variables, max. | 70 |
Forcing |
Forcing | Yes |
Forcing, variables | Inputs/outputs, bit memories, distributed I/Os |
Number of variables, max. | 256 |
Diagnostic buffer |
present | Yes |
Number of entries, max. | 3 200 |
— adjustable | Yes |
— preset | 120 |
Standards, approvals, certificates |
CE mark | Yes |
Ambient conditions |
Ambient temperature during operation |
min. | 0 °C; = Tmin |
max. | 60 °C; = Tmax |
Altitude during operation relating to sea level |
Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
Relative humidity |
With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) |
Resistance |
Use in stationary industrial systems |
— to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
— to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
— to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Configuration |
Configuration software |
STEP 7 | Yes |
Programming |
Command set | see instruction list |
Nesting levels | 8 |
Access to consistent data in process image | Yes |
System functions (SFC) | see instruction list |
System function blocks (SFB) | see instruction list |
Programming language |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
— HiGraph® | Yes |
Number of simultaneously active SFCs |
— RD_REC | 8 |
— WR_REC | 8 |
— WR_PARM | 8 |
— PARM_MOD | 1 |
— WR_DPARM | 2 |
— DPNRM_DG | 8 |
— RDSYSST | 8 |
— DP_TOPOL | 1 |
Number of simultaneously active SFBs |
— RDREC | 8 |
— WRREC | 8 |
Know-how protection |
User program protection/password protection | Yes |
Dimensions |
Width | 50 mm |
Height | 290 mm |
Depth | 219 mm |
Weights |
Weight, approx. | 990 g |
last modified: | 03/13/2019 |