6AG1340-1AH02-2AY0
SIPLUS S7-300 CP340 RS232 EN50155

From SIEMENS

SIPLUS S7-300 CP 340 RS232 -25..+60°C Conformity with EN 50155 with conformal coating based on 6ES7340-1AH02-0AE0. Communications processor with RS232C interface (RS-232-C) incl. configuration package auf CD-ROM
General information
Product type designationCP 340
Supply voltage
Rated value (DC)A power supply according to EN 50155 shall be used
24 V DCNo; Power supply via backplane bus 5V
Input current
from backplane bus 5 V DC, max.165 mA
Power loss
Power loss, typ.0.6 W
Power loss, max.0.85 W
Interfaces
Number of interfaces1; Isolated
Interface physics, RS 232C (V.24)Yes
Transmission rate, min.2.4 kbit/s
Transmission rate, max.19.2 kbit/s
Point-to-point connection
Cable length, max.15 m
supported printersHP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined
Connector type9-pin sub D connector
Integrated protocol driver
— 3964 (R)Yes
— ASCIIYes
— RK512No
— customer-specific drivers reloadableNo
Telegram length, max.
— 3964 (R)1 024 byte
— ASCII1 024 byte
Transmission speed, RS 232
— with 3964 (R) protocol, max.19.2 kbit/s
— with ASCII protocol, max.9.6 kbit/s
— with printer driver, max.9.6 kbit/s
Standards, approvals, certificates
CE markYes
UL approvalYes; File E239877
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
Railway application
EN 50155Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007
Ambient conditions
Ambient temperature during operation
min.-25 °C; = Tmin
max.60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
— to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); *
— to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Remark
— Note regarding classification of environmental conditions acc. to EN 60721* The supplied plug covers must remain in place over the unused interfaces during operation!
Software
Block
FB length in RAM, max.2 700 byte; Data communication, sending and receiving
Connection method
Design of electrical connection for supply voltageOver backplane bus
Dimensions
Width40 mm
Height125 mm
Depth120 mm
Weights
Weight, approx.300 g