| ***Spare part*** SIPLUS ET 200M IM 153-2 (*BA02) -40...+70°C start up temperature: -25°C with conformal coating based on 6ES7153-2BA02-0XB0 Connection ET 200M for max. 12 S7-300 modules with redundancy capability, Timestamping suitable for isochronous mode Operation New features: up to 12 modules can be used Slave Initiative for Drive ES and Switch ES Expanded quantity structure for HART auxiliary variables Operation of the 64-channel modules 32 signals/slot |
General information |
Product type designation | IM 153-2 DP ST |
Vendor identification (VendorID) | 801Eh |
Supply voltage |
Rated value (DC) | |
24 V DC | Yes |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
external protection for power supply lines (recommendation) | 2,5 A |
Mains buffering |
Mains/voltage failure stored energy time | 5 ms |
Input current |
Current consumption, max. | 600 mA |
Inrush current, typ. | 3 A |
I²t | 0.1 A²·s |
Output voltage |
Rated value (DC) | 5 V |
Output current |
for backplane bus (5 V DC), max. | 1.5 A |
Power loss |
Power loss, typ. | 5.5 W |
Address area |
Addressing volume |
Inputs | 244 byte |
Outputs | 244 byte |
Hardware configuration |
Number of modules per DP slave interface, max. | 12 |
Time stamping |
Accuracy | 1 ms; 1ms at up to 8 modules; 10ms at up to 12 modules |
Number of message buffers | 15 |
Messages per message buffer | 20 |
Number of stampable digital inputs, max. | 128; Max. 128 signals/station; max. 32 signals/slot |
Time format | RFC 1119 |
Time resolution | 0.466 ns |
Time interval for transmitting the message buffer if a message is present | 1 000 ms |
Time stamp on signal change | rising / falling edge as signal entering or exiting |
Interfaces |
Transmission procedure | RS 485 |
PROFIBUS DP |
Node addresses | 1 to 125 permitted |
automatic detection of transmission rate | Yes |
Output current, max. | 70 mA |
Transmission rate, max. | 12 Mbit/s |
SYNC capability | Yes |
FREEZE capability | Yes |
Direct data exchange (slave-to-slave communication) | Yes; Sender |
Design of electrical connection of PROFIBUS interface | 9-pin sub D |
1. Interface |
PROFIBUS DP slave |
GSD file | SI04801.GSG |
automatic baud rate search | Yes |
Protocols |
Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 |
Protocols (Ethernet) |
TCP/IP | No |
Potential separation |
Potential separation exists | Yes |
Isolation |
Isolation tested with | Isolation voltage 500 V |
Degree and class of protection |
IP degree of protection | IP20 |
Standards, approvals, certificates |
CE mark | Yes |
UL approval | Yes; File E239877 |
FM approval | Yes; CofC 3028431 |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
EAC (formerly Gost-R) | Yes |
Ambient conditions |
Ambient temperature during operation |
min. | -40 °C; = Tmin |
max. | 70 °C; = Tmax; 60 °C @ UL/cUL use |
At cold restart, min. | -25 °C |
Altitude during operation relating to sea level |
Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
Relative humidity |
With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance |
Use in stationary industrial systems |
— to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
— to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
— to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Configuration |
Configuration software |
STEP 7 | Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file |
Dimensions |
Width | 40 mm |
Height | 125 mm |
Depth | 117 mm |
Weights |
Weight, approx. | 360 g |