4AM3296-0AT70-1NA0
MAINS TRANSFORMER; PHASES:1;

From SIEMENS

MAINS TRANSFORMER; PHASES:1; PN(KVA):0,006; UPRI(V):1000-800-600; USEC(V):100(LEERMAX.104); ISEC(A):0,06; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1 >MAINS TRANSFORMER<
General technical data:
Product designationPower transformer
Product brand nameSIDAC
Operating apparent output rated valueV·A6
Efficiency0.85
Connection method for transformersIi0
Certificate of suitabilityCE
Product function
Temperature monitoringNo
Insulation monitoringNo
Short-circuit and overload proofNo
Number of shielding windings1
Inputs:
Phase number of the inputs1
Input voltage
_1 rated valueV1 000
_2 rated valueV800
_3 rated valueV600
Electrical input frequency
minimumHz50
maximumHz60
Outputs:
Phase number of the outputs1
Electrical output frequency
maximumHz60
minimumHz50
Ambient conditions:
Thermal class acc. to IEC 60085B
Ambient temperature rated value°C50
Protection class IPIP00
Mechanical data:
Type of electrical connection
at output for main current circuitscrew-type terminals / tab terminals
at input for main current circuitscrew-type terminals / tab terminals
Mounting typescrews / standard rail
Construction form of the iron coreEI 84/28
Widthm0.086
Heightm0.098
Depthm0.09

External links