3VA2450-7MS32-0AA0
MCCB_IEC_FS630_500A_3P_110KA_ETU3_AM

From SIEMENS

circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=500A without overload protection short-circuit protection Ii=3...15 x In nut keeper kit
Model
Product brand nameSENTRON
Product designationMolded case circuit breaker
Product versionStarter protection
Design of the overcurrent releaseETU310M
Protective function of the overcurrent releaseI
Number of poles3
General technical data
Rated insulation voltage Ui800 V
Max. rated operational voltage Ue with AC 50/60Hz690 V
Power loss [W] / maximum99 W
Active power loss / for rated value of the current / at AC / in hot operating state / per pole33 W
Latching - endurance15 000
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz4 000
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz4 000
Neutral conductors / upgradeable/retrofittableNo
Ground fault monitoring versionWithout
Product function
communication functionNo
Phase failure detectionNo
other measurement functionNo
Net weight4.826 kg
Electricity
Max. rated operational voltage of the size of the circuit-breaker630 A
Rated continuous current Iu500 A
Operating current
at 40 °C500 A
at 45 °C500 A
at 50 °C500 A
at 55 °C495 A
at 60 °C490 A
at 65 °C485 A
at 70 °C480 A
Switching capacity according to IEC 60947
Switching capacity class of the circuit breakerC
Maximum short-circuit current breaking capacity (Icu)
at 240 V150 kA
at 415 V110 kA
at 440 V110 kA
at 690 V9 kA
Operational short-circuit current breaking capacity (Ics)
at 240 V150 kA
at 415 V110 kA
at 440 V110 kA
at 690 V9 kA
Short-circuit current making capacity (Icm)
at 240 V330 kA
at 415 V242 kA
at 440 V242 kA
at 690 V15.3 kA
Adjustable parameters
Short-term delayed / tripping switchable / I2t=ON/OFFNo
Adjustable response value current / li min.1 500 A
Adjustable response value current / li max.7 500 A
Ground fault protection / tripping switchable / I2t=ON/OFFNo
Mechanical Design
Height [in]9.8 in
Height248 mm
Width [in]5.4 in
Width138 mm
Depth [in]4.3 in
Depth110 mm
Connections
Arrangement of electrical connectors / for main current circuitFront terminal
Type of electrical connection / for main current circuitLug terminal
Type of connectable conductor cross-section, connection screw, width x thickness , min.20 x 1
Type of connectable conductor cross-section, connection screw, width x thickness , max.35 x 10
Auxiliary circuit
Number of CO contacts / for auxiliary contacts0
Accessories
Product extension / optional / motor driveYes
Environmental conditions
Protection class IP / on the frontIP40
Ambient temperature
during operation / minimum-25 °C
during operation / maximum70 °C
during storage / minimum-40 °C
during storage / maximum80 °C