| Contact module with 1 contact element, 1 NC, Contact for installation monitoring, screw terminal, for front plate mounting |
Product brand name | SIRIUS ACT |
Product designation | Contact module |
Product type designation | 3SU1 |
General technical data |
Product function | |
positive opening | Yes |
Insulation voltage | |
rated value | 500 V |
Degree of pollution | 3 |
Type of voltage | |
of the operating voltage | AC/DC |
of the input voltage | AC/DC |
Surge voltage resistance rated value | 6 kV |
Protection class IP | |
of the enclosure | IP40 |
of the terminal | IP20 |
Shock resistance | |
acc. to IEC 60068-2-27 | Sinusoidal half-wave 50 g / 11 ms |
for railway applications acc. to DIN EN 61373 | Category 1, Class B |
Operating frequency maximum | 3 600 1/h |
Mechanical service life (switching cycles) | |
typical | 10 000 000 |
Electrical endurance (switching cycles) | |
typical | 10 000 000 |
Thermal current | 10 A |
Reference code acc. to DIN EN 81346-2 | S |
Reference code acc. to DIN EN 61346-2 | S |
Continuous current of the C characteristic MCB | 10 A |
Operating voltage | |
at AC | |
— at 50 Hz rated value | 5 ... 500 V |
— at 60 Hz rated value | 5 ... 500 V |
at DC | |
— rated value | 5 ... 500 V |
Power Electronics |
Contact reliability | One maloperation per 100 million (17 V, 5 mA), one maloperation per 10 million (5 V, 1 mA) |
Auxiliary circuit |
Design of the contact of auxiliary contacts | Silver alloy |
Number of NC contacts for auxiliary contacts | 1 |
lagging switching | 0 |
Number of NO contacts for auxiliary contacts | 0 |
leading contact | 0 |
Number of CO contacts | |
for auxiliary contacts | 0 |
Operating current at AC-12 | |
at 24 V rated value | 10 A |
at 48 V rated value | 10 A |
at 110 V rated value | 10 A |
at 230 V rated value | 8 A |
at 400 V rated value | 6 A |
Operating current at AC-15 | |
at 24 V rated value | 6 A |
at 48 V rated value | 6 A |
at 110 V rated value | 6 A |
at 230 V rated value | 4 A |
at 400 V rated value | 3 A |
at 500 V rated value | 1.4 A |
Operating current at DC-12 | |
at 24 V rated value | 10 A |
at 48 V rated value | 5 A |
at 110 V rated value | 2.5 A |
at 230 V rated value | 0.3 A |
at 400 V rated value | 0.3 A |
at 500 V rated value | 0.2 A |
Operating current at DC-13 | |
at 24 V rated value | 3 A |
at 48 V rated value | 1.5 A |
at 110 V rated value | 0.6 A |
at 230 V rated value | 0.3 A |
at 400 V rated value | 0.1 A |
at 500 V rated value | 0.1 A |
Connections/Terminals |
Type of electrical connection | screw-type terminals |
Type of connectable conductor cross-sections | |
solid with core end processing | 2x (0.5 ... 0.75 mm²) |
solid without core end processing | 2x (1.0 ... 1.5 mm²) |
finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
finely stranded without core end processing | 2x (1,0 ... 1,5 mm²) |
at AWG conductors | 2x (18 ... 14) |
Tightening torque | |
with screw-type terminals | 0.8 ... 0.9 N·m |
Ambient conditions |
Ambient temperature | |
during operation | -25 ... +70 °C |
during storage | -40 ... +80 °C |
Environmental category during operation acc. to IEC 60721 | 3M6, 3S2, 3B2, 3C3 (without salt spray), 3K6 (with relative humidity of 10 ... 95%, no condensation in operation permitted) |
Installation/ mounting/ dimensions |
Mounting type | |
of modules and accessories | Front plate mounting |
Height | 34 mm |
Width | 9.8 mm |
Depth | 49.7 mm |