3SU1000-1HQ20-0AA0-ZY19
EM. STOP MUSHROOM PUSHBUTTON, 40MM, RED

From SIEMENS

EM. STOP MUSHROOM PUSHBUTTON, 22MM, ROUND, PLASTIC, RED, 40MM, WITH O.M.R. LOCK, LOCK NO. 73037, POSITIVE LATCHING, KEY-OPERATED RELEASE, WITH LASER INSCRIPTION, INSCRIPTION OR GRAPHIC SYMBOL CUSTOMIZED EQUIPMENT USING THE SIRIUS-ACT CONFIGURATOR (CIN)
Product brand nameSIRIUS ACT
Product designationEMERGENCY STOP mushroom pushbuttons
Design of the productActuating/signaling element
Product type designation3SU1
Product linePlastic, black, 22 mm
Enclosure
Number of command points1
Actuator
Design of the operating mechanismpositive latching
Manner of function of the actuating elementlatching
Product extension optional Light sourceNo
Color
of the actuating elementred
Material of the actuating elementplastic
Shape of the actuating elementround
Outer diameter of the actuating element40 mm
Marking of the actuating elementAny inscription, text or symbol, can only be ordered via SIRIUS ACT configurator/Configuration Identification Number (CIN)
Type of unlocking deviceUnlocking
Number of switching positions2
Switch position for key distractionO
Lock makeO.M.R.
Key number73037
Front ring
Product component front ringNo
General technical data
Product function
positive openingYes
EMERGENCY OFF functionYes
EMERGENCY STOP functionYes
Protection class IPIP66, IP67, IP69(IP69K)
Degree of protection NEMA rating1, 2, 3, 3R, 4, 4X, 12, 13
Shock resistance
acc. to IEC 60068-2-27Sinusoidal half-wave 50 g / 11 ms
for railway applications acc. to DIN EN 61373Category 1, Class B
Vibration resistance
acc. to IEC 60068-2-610 ... 500 Hz: 5g
for railway applications acc. to DIN EN 61373Category 1, Class B
Operating frequency maximum600 1/h
Mechanical service life (switching cycles)
typical300 000
Reference code acc. to DIN EN 81346-2S
Reference code acc. to DIN EN 61346-2S
Safety related data
B10 value
with high demand rate acc. to SN 31920100 000
Proportion of dangerous failures
with low demand rate acc. to SN 3192020 %
with high demand rate acc. to SN 3192020 %
Failure rate [FIT]
with low demand rate acc. to SN 31920100 FIT
T1 value for proof test interval or service life acc. to IEC 6150820 y
Ambient conditions
Ambient temperature
during operation-25 ... +70 °C
during storage-40 ... +80 °C
Environmental category during operation acc. to IEC 607213M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95 %)
Installation/ mounting/ dimensions
Shape of the installation openinground
Mounting diameter22.3 mm
Positive tolerance of installation diameter0.4 mm
Mounting height83.3 mm
Installation width40 mm
Installation depth26.3 mm
Certificates/ approvals

External links