3SE5114-0LA00-1AE1
BASIC SWITCH FOR

From SIEMENS

Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 50041 with M12 connector, 5-pole, fixed 1 NO/2 NC quick action contacts (2 NC and PE connected) Max. 125 V, 4 A
Product brand nameSIRIUS
Product designationMechanical safety switches
Product type designation3SE5
Manufacturer's article number
of the supplied basic switch
of the supplied switching contacts
Suitability for use safety switchYes
General technical data
Product function
positive openingYes
Insulation voltage
rated value125 V
Degree of pollutionclass 3
Surge voltage resistance rated value1.5 kV
Protection class IPIP66/IP67
Shock resistance
acc. to IEC 60068-2-2730 g / 11 ms
Vibration resistance
acc. to IEC 60068-2-60.35 mm/5g
Mechanical service life (switching cycles)
typical15 000 000
Electrical endurance (switching cycles) with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 typical10 000 000
Electrical operating cycles in one hour with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT10266 000
Thermal current4 A
Continuous current of the C characteristic MCB1 A; for a short-circuit current smaller than 400 A
Continuous current of the quick DIAZED fuse link4 A; for a short-circuit current smaller than 400 A
Continuous current of the DIAZED fuse link gG4 A
Active principlemechanical
Repeat accuracy0.05 mm
Minimum actuating force in activation direction20 N
Length of the sensor99.7 mm
Width of the sensor40 mm
Design of the switching contactmechanical
Operating frequency rated value50 ... 60 Hz
Number of NC contacts for auxiliary contacts2
Number of NO contacts for auxiliary contacts1
Number of CO contacts for auxiliary contacts1
Operating current at AC-15
at 24 V rated value4 A
at 125 V rated value4 A
Operating current at DC-13
at 24 V rated value3 A
at 125 V rated value0.55 A
Design of the interface for safety-related communicationwithout
Enclosure
Design of the housingblock, narrow
Material of the enclosuremetal
Coating of the enclosurecathodic immersion coating
Design of the housing acc. to standardYes
Drive Head
Design of the operating mechanismOther, without, basic switch with plug
Design of the switching functionPositive opening with appropriate positive opening actuator head
Circuit principlesnap-action contacts
Number of switching contacts safety-related2
Connections/Terminals
Type of electrical connectionM12 plug, fixed
Cable entry typeM12 plug
Design of plug-in connectionM12 plug, 5-pole: Pin 1 = terminal 21, Pin 2 = 22, Pin 3 = 31, Pin 4 = 32, Pin 5 = PU
Communication/ Protocol
Design of the interfacewithout
Ambient conditions
Ambient temperature
during operation-25 ... +85 °C
during storage-40 ... +90 °C
Explosion protection category for dustnone
Installation/ mounting/ dimensions
Mounting positionany
Mounting typescrew fixing

External links