| SIRIUS soft starter 200-600 V 143 A, 24 V AC/DC spring-type terminals Thermistor input |
Product brand name | SIRIUS |
Product category | Hybrid switching devices |
Product designation | Soft starter |
Product type designation | 3RW52 |
Manufacturer's article number | |
of HMI module usable | |
of HMI-Modul high-feature usable | |
of communication module PROFINET standard usable | |
of communication module PROFIBUS usable | |
of communication module Modbus TCP usable | |
of communication module Modbus RTU usable | |
of communication module Ethernet/IP | |
of circuit breaker usable at 400 V | |
of circuit breaker usable at 400 V at inside-delta circuit | |
of the gG fuse usable up to 690 V | |
of the gG fuse usable at inside-delta circuit up to 500 V | |
of full range R fuse link for semiconductor protection usable up to 690 V | |
of back-up R fuse link for semiconductor protection usable up to 690 V | |
General technical data |
Starting voltage [%] | 30 ... 100 % |
Stopping voltage [%] | 50 ... 50 % |
Start-up ramp time of soft starter | 0 ... 20 s |
Current limiting value [%] adjustable | 130 ... 700 % |
Certificate of suitability | |
CE marking | Yes |
UL approval | Yes |
CSA-approval | Yes |
Product component | |
is supported HMI-Standard | Yes |
is supported HMI-High Feature | Yes |
Product feature integrated bypass contact system | Yes |
Number of controlled phases | 3 |
Trip class | CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2 |
Insulation voltage | |
rated value | 600 V |
Degree of pollution | 3, acc. to IEC 60947-4-2 |
Impulse voltage rated value | 6 kV |
Blocking voltage of the thyristor maximum | 1 800 V |
Service factor | 1 |
Surge voltage resistance rated value | 6 kV |
maximum permissible voltage for safe isolation | |
between main and auxiliary circuit | 600 V |
Protection class IP | IP00 |
Usage category acc. to IEC 60947-4-2 | AC 53a |
Shock resistance | 15 g / 11 ms, from 12 g / 11 ms with potential contact lifting |
Vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
Reference code acc. to DIN EN 81346-2 | Q |
Product function | |
ramp-up (soft starting) | Yes |
ramp-down (soft stop) | Yes |
Soft Torque | Yes |
Adjustable current limitation | Yes |
pump ramp down | Yes |
Intrinsic device protection | Yes |
motor overload protection | Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) |
Evaluation of thermistor motor protection | Yes; Type A PTC or Klixon / Thermoclick |
inside-delta circuit | Yes |
Auto-reset | Yes |
Manual RESET | Yes |
remote reset | Yes; By turning off the control supply voltage |
communication function | Yes |
operating measured value display | Yes; Only in conjunction with special accessories |
error logbook | Yes; Only in conjunction with special accessories |
via software parameterizable | No |
via software configurable | Yes |
PROFIenergy | Yes; in connection with the PROFINET Standard communication module |
firmware update | Yes |
removable terminal for control circuit | Yes |
torque control | No |
analog output | No |
Power Electronics |
Operating current | |
at 40 °C rated value | 143 A |
at 50 °C rated value | 128 A |
at 60 °C rated value | 118 A |
Operating current at inside-delta circuit | |
at 40 °C rated value | 248 A |
at 50 °C rated value | 222 A |
at 60 °C rated value | 204 A |
Operating voltage | |
rated value | 200 ... 600 V |
at inside-delta circuit rated value | 200 ... 600 V |
Relative negative tolerance of the operating voltage | -15 % |
Relative positive tolerance of the operating voltage | 10 % |
Relative negative tolerance of the operating voltage at inside-delta circuit | -15 % |
Relative positive tolerance of the operating voltage at inside-delta circuit | 10 % |
Operating power for three-phase motors | |
at 230 V at 40 °C rated value | 37 kW |
at 230 V at inside-delta circuit at 40 °C rated value | 75 kW |
at 400 V at 40 °C rated value | 75 kW |
at 400 V at inside-delta circuit at 40 °C rated value | 132 kW |
at 500 V at 40 °C rated value | 90 kW |
at 500 V at inside-delta circuit at 40 °C rated value | 160 kW |
Operating frequency 1 rated value | 50 Hz |
Operating frequency 2 rated value | 60 Hz |
Relative negative tolerance of the operating frequency | -10 % |
Relative positive tolerance of the operating frequency | 10 % |
Adjustable motor current | |
at rotary encoding switch on switch position 1 | 68 A |
at rotary encoding switch on switch position 2 | 73 A |
at rotary encoding switch on switch position 3 | 78 A |
at rotary encoding switch on switch position 4 | 83 A |
at rotary encoding switch on switch position 5 | 88 A |
at rotary encoding switch on switch position 6 | 93 A |
at rotary encoding switch on switch position 7 | 98 A |
at rotary encoding switch on switch position 8 | 103 A |
at rotary encoding switch on switch position 9 | 108 A |
at rotary encoding switch on switch position 10 | 113 A |
at rotary encoding switch on switch position 11 | 118 A |
at rotary encoding switch on switch position 12 | 123 A |
at rotary encoding switch on switch position 13 | 128 A |
at rotary encoding switch on switch position 14 | 133 A |
at rotary encoding switch on switch position 15 | 138 A |
at rotary encoding switch on switch position 16 | 143 A |
minimum | 68 A |
Adjustable motor current | |
for inside-delta circuit at rotary encoding switch on switch position 1 | 118 A |
for inside-delta circuit at rotary encoding switch on switch position 2 | 126 A |
for inside-delta circuit at rotary encoding switch on switch position 3 | 135 A |
for inside-delta circuit at rotary encoding switch on switch position 4 | 144 A |
for inside-delta circuit at rotary encoding switch on switch position 5 | 152 A |
for inside-delta circuit at rotary encoding switch on switch position 6 | 161 A |
for inside-delta circuit at rotary encoding switch on switch position 7 | 170 A |
for inside-delta circuit at rotary encoding switch on switch position 8 | 178 A |
for inside-delta circuit at rotary encoding switch on switch position 9 | 187 A |
for inside-delta circuit at rotary encoding switch on switch position 10 | 196 A |
for inside-delta circuit at rotary encoding switch on switch position 11 | 204 A |
for inside-delta circuit at rotary encoding switch on switch position 12 | 213 A |
for inside-delta circuit at rotary encoding switch on switch position 13 | 222 A |
for inside-delta circuit at rotary encoding switch on switch position 14 | 230 A |
for inside-delta circuit at rotary encoding switch on switch position 15 | 239 A |
for inside-delta circuit at rotary encoding switch on switch position 16 | 248 A |
at inside-delta circuit minimum | 118 A |
Minimum load [%] | 15 %; Relative to smallest settable Ie |
Power loss [W] for rated value of the current at AC | |
at 40 °C to power-up | 55 W |
at 50 °C to power-up | 50 W |
at 60 °C to power-up | 47 W |
Power loss [W] at AC at AC | |
at 40 °C during startup | 2 127 W |
at 50 °C during startup | 1 807 W |
at 60 °C during startup | 1 605 W |
Control circuit/ Control |
Type of voltage of the control supply voltage | AC/DC |
Control supply voltage at AC | |
at 50 Hz rated value | 24 V |
at 60 Hz rated value | 24 V |
Relative negative tolerance of the control supply voltage at AC at 50 Hz | -20 % |
Relative positive tolerance of the control supply voltage at AC at 50 Hz | 20 % |
Relative negative tolerance of the control supply voltage at AC at 60 Hz | -20 % |
Relative positive tolerance of the control supply voltage at AC at 60 Hz | 20 % |
Control supply voltage frequency | 50 ... 60 Hz |
Relative negative tolerance of the control supply voltage frequency | -10 % |
Relative positive tolerance of the control supply voltage frequency | 10 % |
Control supply voltage | |
at DC rated value | 24 V |
Relative negative tolerance of the control supply voltage at DC | -20 % |
Relative positive tolerance of the control supply voltage at DC | 20 % |
Control supply current in standby mode rated value | 160 mA |
Holding current in the by-pass mode operating rated value | 380 mA |
Starting current at close of by-pass contact maximum | 7.6 A |
Inrush current peak at connect of control supply voltage maximum | 3.3 A |
Duration of inrush current peak at connect of control supply voltage | 12.1 ms |
Design of the overvoltage protection | Varistor |
Design of short-circuit protection for control circuit | 4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply |
Inputs/ Outputs |
Number of digital inputs | 1 |
Number of inputs for thermistor connection | 1; Type A PTC or Klixon / Thermoclick |
Number of digital outputs | 3 |
not parameterizable | 2 |
Digital output version | 2 normally-open contacts (NO) / 1 changeover contact (CO) |
Number of analog outputs | 0 |
Switching capacity current of the relay outputs | |
at AC-15 at 250 V rated value | 3 A |
at DC-13 at 24 V rated value | 1 A |
Installation/ mounting/ dimensions |
Mounting position | with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
Mounting type | screw fixing |
Height | 306 mm |
Width | 185 mm |
Depth | 203 mm |
Required spacing with side-by-side mounting | |
forwards | 10 mm |
Backwards | 0 mm |
upwards | 100 mm |
downwards | 75 mm |
at the side | 5 mm |
Installation altitude at height above sea level maximum | 5 000 m; Derating as of 1000 m, see catalog |
Weight without packaging | 6.6 kg |
Connections/ Terminals |
Type of electrical connection | |
for main current circuit | busbar connection |
for control circuit | spring-loaded terminals |
Width of connection bar maximum | 25 mm |
Type of connectable conductor cross-sections | |
for DIN cable lug for main contacts stranded | 2x (16 ... 95 mm²) |
for DIN cable lug for main contacts finely stranded | 2x (25 ... 120 mm²) |
Type of connectable conductor cross-sections | |
for control circuit solid | 2x (0.25 ... 1.5 mm²) |
for control circuit finely stranded with core end processing | 2x (0.25 ... 1.5 mm²) |
at AWG conductors for control circuit solid | 2x (24 ... 16) |
at AWG conductors for control circuit finely stranded with core end processing | 2x (24 ... 16) |
Wire length | |
between soft starter and motor maximum | 800 m |
at the digital inputs at AC maximum | 100 m |
at the digital inputs at DC maximum | 1 000 m |
Tightening torque | |
for main contacts with screw-type terminals | 10 ... 14 N·m |
for auxiliary and control contacts with screw-type terminals | 0.8 ... 1.2 N·m |
Tightening torque [lbf·in] | |
for main contacts with screw-type terminals | 89 ... 124 lbf·in |
for auxiliary and control contacts with screw-type terminals | 7 ... 10.3 lbf·in |
Ambient conditions |
Ambient temperature | |
during operation | -25 ... +60 °C; Please observe derating at temperatures of 40 °C or above |
during storage and transport | -40 ... +80 °C |
Environmental category | |
during operation acc. to IEC 60721 | 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
during storage acc. to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
during transport acc. to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
EMC emitted interference | acc. to IEC 60947-4-2: Class A |
Communication/ Protocol |
Communication module is supported | |
PROFINET standard | Yes |
EtherNet/IP | Yes |
Modbus RTU | Yes |
Modbus TCP | Yes |
PROFIBUS | Yes |
UL/CSA ratings |
Manufacturer's article number | |
of circuit breaker | |
— usable for Standard Faults at 460/480 V according to UL | Siemens type: 3VA52, max. 250 A; Iq = 10 kA |
— usable for High Faults at 460/480 V according to UL | Siemens type: 3VA52, max. 250 A; Iq max = 65 kA |
— usable for Standard Faults at 460/480 V at inside-delta circuit according to UL | Siemens type: 3VA52, max. 250 A; Iq = 10 kA |
— usable for High Faults at 460/480 V at inside-delta circuit according to UL | Siemens type: 3VA52, max. 250 A; Iq max = 65 kA |
— usable for Standard Faults at 575/600 V according to UL | Siemens type: 3VA52, max. 250 A; Iq = 10 kA |
— usable for Standard Faults at 575/600 V at inside-delta circuit according to UL | Siemens type: 3VA52, max. 250 A; Iq = 10 kA |
of the fuse | |
— usable for Standard Faults up to 575/600 V according to UL | Type: Class RK5 / K5, max. 350 A; Iq = 10 kA |
— usable for High Faults up to 575/600 V according to UL | Type: Class J / L, max. 350 A; Iq = 100 kA |
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to UL | Type: Class RK5 / K5, max. 350 A; Iq = 10 kA |
— usable for High Faults at inside-delta circuit up to 575/600 V according to UL | Type: Class J / L, max. 350 A; Iq = 100 kA |
Operating power [hp] for three-phase motors | |
at 200/208 V at 50 °C rated value | 40 hp |
at 220/230 V at 50 °C rated value | 40 hp |
at 460/480 V at 50 °C rated value | 100 hp |
at 575/600 V at 50 °C rated value | 125 hp |
at 200/208 V at inside-delta circuit at 50 °C rated value | 75 hp |
at 220/230 V at inside-delta circuit at 50 °C rated value | 75 hp |
at 460/480 V at inside-delta circuit at 50 °C rated value | 150 hp |
at 575/600 V at inside-delta circuit at 50 °C rated value | 200 hp |
Contact rating of auxiliary contacts according to UL | R300-B300 |
Safety related data |
Electromagnetic compatibility | in accordance with IEC 60947-4-2 |