3RT2617-1AP05
CONT., AC6B:12.5KVAR 2NC 230VAC 50/60HZ

From SIEMENS

Capacitor contactor, AC-6b 12.5 kVAr, / 400 V 2 NC, 230 V AC, 50/60 Hz 3-pole, Size S00 screw terminal
Product brand nameSIRIUS
Product designationcapacitor contactors
Product type designation3RT26
General technical data
Size of contactorS00
Product extension
Auxiliary switchNo
Surge voltage resistance
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation
between coil and main contacts acc. to EN 60947-1400 V
Protection class IP
on the frontIP20
of the terminalIP20
Shock resistance at rectangular impulse
at AC6,7g / 5 ms, 4,2g / 10 ms
Shock resistance with sine pulse
at AC10,5g / 5 ms, 6,6g / 10 ms
Mechanical service life (switching cycles)
of the contactor with added auxiliary switch block typical3 000 000
Electrical endurance (switching cycles)300 000
Reference code acc. to DIN EN 81346-2Q
Ambient conditions
Installation altitude at height above sea level
maximum2 000 m
Ambient temperature
during operation-25 ... +60 °C
during storage-55 ... +80 °C
Main circuit
Number of NO contacts for main contacts3
Number of NC contacts for main contacts0
Operating current
at AC-6b at 690 V at ambient temperature 60 °C rated value18 A
Operational reactive power at AC-6b
at 230 V at 50/60 Hz at ambient temperature 60 °C rated value0 ... 7.2 kvar
at 400 V at 50/60 Hz at ambient temperature 60 °C rated value0 ... 12.5 kvar
at 500 V at 50/60 Hz at ambient temperature 60 °C rated value0 ... 15 kvar
at 690 V at 50/60 Hz at ambient temperature 60 °C rated value0 ... 21 kvar
No-load switching frequency
at AC500 1/h
Operating frequency at AC-6b
at 230 V maximum180 1/h
at 240 V maximum180 1/h
at 400 V maximum180 1/h
at 480 V maximum180 1/h
at 500 V maximum180 1/h
at 600 V maximum180 1/h
at 690 V maximum180 1/h
Control circuit/ Control
Type of voltageAC
Type of voltage of the control supply voltageAC
Control supply voltage at AC
at 50 Hz rated value230 V
at 60 Hz rated value230 V
Control supply voltage frequency
1 rated value50 Hz
2 rated value60 Hz
Operating range factor control supply voltage rated value of magnet coil at AC
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
Apparent pick-up power of magnet coil at AC49 V·A
Inductive power factor with closing power of the coil0.8
Apparent holding power of magnet coil at AC7.8 V·A
Inductive power factor with the holding power of the coil0.25
Closing delay
at AC8 ... 33 ms
Arcing time10 ... 15 ms
Residual current of the electronics for control with signal <0>
at AC at 230 V maximum permissible3 mA
Auxiliary circuit
Number of NC contacts for auxiliary contacts2
attachable0
instantaneous contact2
Number of NO contacts for auxiliary contacts0
attachable0
instantaneous contact0
Operating current of auxiliary contacts at AC-12 maximum10 A
Operating current of auxiliary contacts at AC-15
at 230 V6 A
at 400 V3 A
Operating current of auxiliary contacts at DC-13
at 24 V6 A
at 60 V2 A
at 110 V1 A
at 125 V0.9 A
at 220 V0.3 A
Contact reliability of auxiliary contacts0.00000001
UL/CSA ratings
Contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
Design of the fuse link
for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG: 40 A (690 V, 50 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Height125 mm
Width45 mm
Depth120 mm
Required spacing
with side-by-side mounting
— at the side10 mm
for grounded parts
— at the side10 mm
Connections/Terminals
Type of electrical connection
for main current circuitscrew-type terminals
for auxiliary and control current circuitscrew-type terminals
Type of connectable conductor cross-sections
for main contacts
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— single or multi-stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
at AWG conductors for main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Type of connectable conductor cross-sections
for auxiliary contacts
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— single or multi-stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
at AWG conductors for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Type of minimum connectable cross-section for main contacts at AC-6b
at 40 °C1x 4 mm², 2x 2.5 mm²
at 60 °C2x 4 mm²
AWG number as coded connectable conductor cross section for main contacts20 ... 12
Safety related data
Product function
Mirror contact acc. to IEC 60947-4-1No
positively driven operation acc. to IEC 60947-5-1No
Protection against electrical shockfinger-safe