| Power contactor, AC-3 40 A, 18.5 kW / 400 V 2 NO + 2 NC 175-280 V AC/DC 4-pole size S2 screw terminals 1 NO + 1 NC integrated |
Product brand name | SIRIUS |
Product designation | contactor |
Product type designation | 3RT25 |
General technical data |
Size of contactor | S2 |
Product extension | |
function module for communication | No |
Auxiliary switch | Yes |
Surge voltage resistance | |
of main circuit rated value | 6 kV |
of auxiliary circuit rated value | 6 kV |
maximum permissible voltage for safe isolation | |
between coil and main contacts acc. to EN 60947-1 | 400 V |
Protection class IP | |
on the front | IP20 |
of the terminal | IP00 |
Shock resistance at rectangular impulse | |
at AC | 7.7g / 5 ms, 4.5g / 10 ms |
at DC | 7.7g / 5 ms, 4.5g / 10 ms |
Shock resistance with sine pulse | |
at AC | 12g / 5 ms, 7g / 10 ms |
at DC | 12g / 5 ms, 7g / 10 ms |
Mechanical service life (switching cycles) | |
of contactor typical | 10 000 000 |
of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 |
of the contactor with added auxiliary switch block typical | 10 000 000 |
Reference code acc. to DIN EN 81346-2 | Q |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 2 000 m |
Main circuit |
Number of poles for main current circuit | 4 |
Number of NO contacts for main contacts | 2 |
Number of NC contacts for main contacts | 2 |
Operating current | |
at AC-1 | |
— up to 690 V at ambient temperature 40 °C rated value | 60 A |
— up to 690 V at ambient temperature 60 °C rated value | 55 A |
at AC-2 at AC-3 at 400 V | |
— per NO contact rated value | 35 A |
— per NC contact rated value | 35 A |
Connectable conductor cross-section in main circuit at AC-1 | |
at 60 °C minimum permissible | 16 mm² |
at 40 °C minimum permissible | 16 mm² |
Operating current | |
at 1 current path at DC-1 | |
— at 24 V rated value | 55 A |
— at 110 V rated value | 4.5 A |
— at 220 V rated value | 1 A |
— at 440 V rated value | 0.4 A |
with 2 current paths in series at DC-1 | |
— at 24 V rated value | 55 A |
— at 110 V rated value | 45 A |
— at 220 V rated value | 5 A |
— at 440 V rated value | 1 A |
Operating current | |
at 1 current path at DC-3 at DC-5 | |
— at 24 V per NC contact rated value | 35 A |
— at 24 V per NO contact rated value | 35 A |
— at 110 V per NC contact rated value | 1.25 A |
— at 110 V per NO contact rated value | 2.5 A |
— at 220 V per NC contact rated value | 0.5 A |
— at 220 V per NO contact rated value | 1 A |
— at 440 V per NC contact rated value | 0.045 A |
— at 440 V per NO contact rated value | 0.1 A |
with 2 current paths in series at DC-3 at DC-5 | |
— at 24 V per NC contact rated value | 55 A |
— at 24 V per NO contact rated value | 55 A |
— at 110 V per NC contact rated value | 12.5 A |
— at 110 V per NO contact rated value | 25 A |
— at 220 V per NC contact rated value | 2.5 A |
— at 220 V per NO contact rated value | 5 A |
— at 440 V per NC contact rated value | 0.135 A |
— at 440 V per NO contact rated value | 0.27 A |
Operating power | |
at AC-1 | |
— at 230 V rated value | 23 kW |
— at 400 V rated value | 39 kW |
at AC-2 at AC-3 | |
— at 230 V per NC contact rated value | 11 kW |
— at 230 V per NO contact rated value | 11 kW |
— at 400 V per NC contact rated value | 18.5 kW |
— at 400 V per NO contact rated value | 18.5 kW |
Thermal short-time current limited to 10 s | 420 A |
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 4 W |
No-load switching frequency | |
at AC | 500 1/h |
at DC | 500 1/h |
Operating frequency | |
at AC-1 maximum | 350 1/h |
Control circuit/ Control |
Type of voltage of the control supply voltage | AC/DC |
Control supply voltage at AC | |
at 50 Hz rated value | 175 ... 280 V |
at 60 Hz rated value | 175 ... 280 V |
Control supply voltage at DC | |
rated value | 175 ... 280 V |
Operating range factor control supply voltage rated value of magnet coil at DC | |
initial value | 0.8 |
Full-scale value | 1.1 |
Operating range factor control supply voltage rated value of magnet coil at AC | |
at 50 Hz | 0.8 ... 1.1 |
at 60 Hz | 0.8 ... 1.1 |
Design of the surge suppressor | with varistor |
Apparent pick-up power of magnet coil at AC | 110 V·A |
at 50 Hz | 110 V·A |
at 60 Hz | 110 V·A |
Inductive power factor with closing power of the coil | 0.72 |
at 50 Hz | 0.95 |
at 60 Hz | 0.95 |
Apparent holding power of magnet coil at AC | 2.5 V·A |
at 50 Hz | 2.5 V·A |
at 60 Hz | 2.5 V·A |
Inductive power factor with the holding power of the coil | 0.95 |
at 50 Hz | 0.95 |
at 60 Hz | 0.95 |
Closing power of magnet coil at DC | 70 W |
Holding power of magnet coil at DC | 1.5 W |
Closing delay | |
at AC | 30 ... 70 ms |
at DC | 30 ... 70 ms |
Opening delay | |
at AC | 30 ... 55 ms |
at DC | 30 ... 55 ms |
Arcing time | 10 ... 20 ms |
Control version of the switch operating mechanism | UC |
Residual current of the electronics for control with signal <0> | |
at AC at 230 V maximum permissible | 20 A |
at DC at 24 V maximum permissible | 20 A |
Auxiliary circuit |
Number of NC contacts for auxiliary contacts | |
instantaneous contact | 1 |
Number of NO contacts for auxiliary contacts | |
instantaneous contact | 1 |
Operating current at AC-12 maximum | 10 A |
Operating current at AC-15 | |
at 230 V rated value | 6 A |
at 400 V rated value | 3 A |
at 500 V rated value | 2 A |
at 690 V rated value | 1 A |
Operating current at DC-12 | |
at 24 V rated value | 10 A |
at 48 V rated value | 6 A |
at 60 V rated value | 6 A |
at 110 V rated value | 3 A |
at 125 V rated value | 2 A |
at 220 V rated value | 1 A |
at 600 V rated value | 0.15 A |
Operating current at DC-13 | |
at 24 V rated value | 10 A |
at 48 V rated value | 2 A |
at 60 V rated value | 2 A |
at 110 V rated value | 1 A |
at 125 V rated value | 0.9 A |
at 220 V rated value | 0.3 A |
at 600 V rated value | 0.1 A |
Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
UL/CSA ratings |
Contact rating of auxiliary contacts according to UL | A600 / P600 |
Short-circuit protection |
Design of the fuse link | |
for short-circuit protection of the main circuit | |
— with type of coordination 1 required | gG: 125 A (690 V, 100 kA) |
— with type of assignment 2 required | gG: 63A (690V, 100kA) |
for short-circuit protection of the auxiliary switch required | fuse gG: 10 A |
Installation/ mounting/ dimensions |
Mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
Side-by-side mounting | Yes |
Height | 114 mm |
Width | 75 mm |
Depth | 130 mm |
Required spacing | |
with side-by-side mounting | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
for grounded parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 50 mm |
— at the side | 10 mm |
— downwards | 50 mm |
for live parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 50 mm |
— downwards | 50 mm |
— at the side | 10 mm |
Connections/Terminals |
Type of electrical connection | |
for main current circuit | screw-type terminals |
for auxiliary and control current circuit | screw-type terminals |
Type of connectable conductor cross-sections | |
for main contacts | |
— solid | 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) |
— single or multi-stranded | 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) |
— finely stranded with core end processing | 2x (1 ... 25 mm²), 1x (1 ... 35 mm²) |
at AWG conductors for main contacts | 2x (18 ... 2), 1x (18 ... 1) |
Type of connectable conductor cross-sections | |
for auxiliary contacts | |
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
— single or multi-stranded | 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²) |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
at AWG conductors for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14) |
AWG number as coded connectable conductor cross section for main contacts | 18 ... 1 |
Safety related data |
Product function | |
Mirror contact acc. to IEC 60947-4-1 | Yes |
positively driven operation acc. to IEC 60947-5-1 | No |
Protection against electrical shock | finger-safe when touched vertically from front acc. to IEC 60529 |