| Timing relay, Multifunction Phased-out product !!! For further information, please contact our sales department 2 change-over contacts, 16 functions 15 time ranges (0.05 s-100 h) 24 V 200-240 V AC and 24 V DC at 50/60 Hz AC with LED, Screw terminal |
Product brand name | SIRIUS |
Product designation | timing relay |
Product type designation | 3RP15 |
General technical data |
Product component | |
Relay output | Yes |
semi-conductor output | No |
Product extension required remote control | No |
Product extension optional remote control | No |
Power loss [W] total typical | 2 W |
Insulation voltage | |
for overvoltage category III according to IEC 60664 | |
— with degree of pollution 3 rated value | 300 V |
Test voltage for isolation test | 2 kV |
Degree of pollution | 3 |
Surge voltage resistance rated value | 4 000 V |
Protection class IP | IP20 |
Shock resistance | |
acc. to IEC 60068-2-27 | 11g / 15 ms |
Mechanical service life (switching cycles) | |
typical | 10 000 000 |
Electrical endurance (switching cycles) | |
at AC-15 at 230 V typical | 100 000 |
Adjustable time | 0.05 s ... 100 h |
Relative setting accuracy relating to full-scale value | 5 % |
Thermal current | 5 A |
Minimum ON period | 35 ms |
Recovery time | 150 ms |
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | K |
Reference code acc. to DIN EN 81346-2 | K |
Reference code acc. to DIN EN 61346-2 | K |
Relative repeat accuracy | 1 % |
Control circuit/ Control |
Type of voltage of the control supply voltage | AC/DC |
Control supply voltage 1 at AC | |
at 50 Hz rated value | 24 V |
at 60 Hz rated value | 24 V |
Control supply voltage 2 at AC | |
at 50 Hz | 200 ... 240 V |
at 60 Hz | 200 ... 240 V |
Control supply voltage frequency 1 | 50 ... 60 Hz |
Control supply voltage 1 | |
at DC rated value | 24 V |
Operating range factor control supply voltage rated value at DC | |
initial value | 0.85 |
Full-scale value | 1.1 |
Operating range factor control supply voltage rated value at AC at 50 Hz | |
initial value | 0.85 |
Full-scale value | 1.1 |
Operating range factor control supply voltage rated value at AC at 60 Hz | |
initial value | 0.85 |
Full-scale value | 1.1 |
Switching Function |
Switching function | |
ON-delay | Yes |
ON-delay/instantaneous contact | Yes |
passing make contact | Yes |
passing make contact/instantaneous contact | Yes |
OFF delay | No |
Switching function | |
flashing symmetrically starting with interval/instantaneous | Yes |
flashing symmetrically starting with interval | Yes |
flashing symmetrically starting with pulse/instantaneous | No |
flashing symmetrically starting with pulse | No |
flashing asymmetrically starting with interval | No |
flashing asymmetrically starting with pulse | No |
Switching function | |
star-delta circuit with delay time | No |
star-delta circuit | Yes |
Switching function with control signal | |
additive ON delay | Yes |
passing break contact | Yes |
passing break contact/instantaneous | Yes |
OFF delay | Yes |
OFF delay/instantaneous | Yes |
pulse delayed | No |
pulse delayed/instantaneous | No |
pulse-shaping | Yes |
pulse-shaping/instantaneous | Yes |
additive ON delay/instantaneous | Yes |
ON-delay/OFF-delay/instantaneous | Yes |
passing make contact | No |
passing make contact/instantaneous contact | No |
Switching function of interval relay with control signal | |
retrotriggerable with deactivated control signal/instantaneous contact | No |
retrotriggerable with activated control signal | No |
retrotriggerable with activated control signal/instantaneous contact | No |
retriggerable with deactivated control signal | No |
Design of the control terminal non-floating | Yes |
Short-circuit protection |
Design of the fuse link | |
for short-circuit protection of the auxiliary switch required | fuse gL/gG: 4 A |
Auxiliary circuit |
Material of switching contacts | AgSnO2 |
Number of CO contacts | |
delayed switching | 2 |
Operating current of auxiliary contacts at AC-15 | |
at 24 V | 3 A |
at 250 V | 3 A |
Operating current of auxiliary contacts at DC-13 | |
at 24 V | 1 A |
at 125 V | 0.2 A |
at 250 V | 0.1 A |
Operating frequency with 3RT2 contactor maximum | 5 000 1/h |
Contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) |
Contact rating of auxiliary contacts according to UL | R300 / B300 |
Influence of the surrounding temperature | ±5 % |
Power supply influence | ±1 % |
Inputs/ Outputs |
Product function | |
non-volatile | No |
Electromagnetic compatibility |
EMI immunity | |
acc. to IEC 61812-1 | EN 61000-6-2 |
Conducted interference | |
due to burst acc. to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
due to conductor-earth surge acc. to IEC 61000-4-5 | 2 kV |
due to conductor-conductor surge acc. to IEC 61000-4-5 | 1 kV |
Field-bound parasitic coupling acc. to IEC 61000-4-3 | 10 V/m |
Electrostatic discharge acc. to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
Safety related data |
Protection against electrical shock | finger-safe |
Type of insulation | Basic insulation |
Category acc. to EN 954-1 | none |
Connections/Terminals |
Product function | |
removable terminal for auxiliary and control circuit | Yes |
Type of electrical connection | |
for auxiliary and control current circuit | screw-type terminals |
Type of connectable conductor cross-sections | |
solid | 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) |
finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
at AWG conductors solid | 2x (20 ... 14) |
at AWG conductors stranded | 2x (20 ... 14) |
Connectable conductor cross-section | |
solid | 0.5 ... 4 mm² |
finely stranded with core end processing | 0.5 ... 2.5 mm² |
AWG number as coded connectable conductor cross section | |
solid | 20 ... 14 |
stranded | 20 ... 14 |
Tightening torque | 0.8 ... 1.2 N·m |
Design of the thread of the connection screw | M3 |
Installation/ mounting/ dimensions |
Mounting position | any |
Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail |
Height | 102 mm |
Width | 22.5 mm |
Depth | 91 mm |
Required spacing | |
with side-by-side mounting | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
for grounded parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— at the side | 0 mm |
— downwards | 0 mm |
for live parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 2 000 m |
Ambient temperature | |
during operation | -25 ... +60 °C |
during storage | -40 ... +85 °C |
during transport | -40 ... +85 °C |
Relative humidity | |
during operation | 10 ... 95 % |