| Motor starter SIRIUS 3RM1 Reversing starter 500 V; 1.6-7.0 A; 110-230 V AC Push-in connection method |
Product brand name | SIRIUS |
Product category | Motor starter |
Product designation | Reversing starter |
Design of the product | with electronic overload protection |
Product type designation | 3RM1 |
General technical data |
Trip class | CLASS 10A |
Product function | |
Intrinsic device protection | Yes |
Suitability for operation Device connector 3ZY12 | No |
Power loss [W] typical | 3.4 W |
Insulation voltage | |
rated value | 500 V |
Surge voltage resistance rated value | 6 kV |
maximum permissible voltage for safe isolation | |
between main and auxiliary circuit | 500 V |
between control and auxiliary circuit | 250 V |
Protection class IP | IP20 |
Shock resistance | 6g / 11 ms |
Operating frequency maximum | 1 1/s |
Mechanical service life (switching cycles) | |
typical | 30 000 000 |
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | Q |
Reference code acc. to DIN EN 81346-2 | Q |
Reference code acc. to DIN EN 61346-2 | Q |
Product function | |
direct start | No |
reverse starting | Yes |
Product function Short circuit protection | No |
Electromagnetic compatibility |
Conducted interference | |
due to burst acc. to IEC 61000-4-4 | 3 kV / 5 kHz |
due to conductor-earth surge acc. to IEC 61000-4-5 | 2 kV |
due to conductor-conductor surge acc. to IEC 61000-4-5 | 1 kV |
due to high-frequency radiation acc. to IEC 61000-4-6 | 10 V |
Electrostatic discharge acc. to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
Conducted HF-interference emissions acc. to CISPR11 | Class B for domestic, business and commercial environments; Class A for industrial environments at 110 V DC |
Field-bound HF-interference emission acc. to CISPR11 | Class B for domestic, business and commercial environments; Class A for industrial environments at 110 V DC |
Safety related data |
Protection against electrical shock | finger-safe |
Main circuit |
Number of poles for main current circuit | 3 |
Design of the switching contact as NO contact for signaling function | OUT, electronic, 24 V DC, 15 mA |
Adjustable pick-up value current of the current-dependent overload release | 1.6 ... 7 A |
Minimum load [%] | 20 % |
Type of the motor protection | solid-state |
Operating voltage | |
rated value | 48 ... 500 V |
Relative symmetrical tolerance of the operating voltage | 10 % |
Operating frequency 1 rated value | 50 Hz |
Operating frequency 2 rated value | 60 Hz |
Relative symmetrical tolerance of the operating frequency | 10 % |
Operating current | |
at AC at 400 V rated value | 7 A |
at AC-53a at 400 V at ambient temperature 40 °C rated value | 7 A |
Ampacity when starting maximum | 56 A |
Operating power for three-phase motors at 400 V at 50 Hz | 0.55 ... 3 kW |
Derating temperature | 40 °C |
Inputs/ Outputs |
Input voltage at digital input | |
at DC rated value | 110 V |
with signal <0> at DC | 0 ... 40 V |
for signal <1> at DC | 79 ... 121 |
Input voltage at digital input | |
at AC rated value | 110 V |
with signal <0> at AC | 0 ... 40 V |
for signal <1> at AC | 93 ... 253 V |
Input current at digital input | |
with signal <0> typical | 0.0004 A |
for signal <1> typical | 0.002 A |
Input current at digital input | |
for signal <1> at DC | 1.5 mA |
with signal <0> at DC | 0.25 mA |
Input current at digital input with signal <0> at AC | |
at 110 V | 0.2 mA |
at 230 V | 0.4 mA |
Input current at digital input for signal <1> at AC | |
at 110 V | 1.1 mA |
at 230 V | 2.3 mA |
Number of CO contacts for auxiliary contacts | 1 |
Operating current of auxiliary contacts at AC-15 at 230 V maximum | 3 A |
Operating current of auxiliary contacts at DC-13 at 24 V maximum | 1 A |
Control circuit/ Control |
Type of voltage of the control supply voltage | AC/DC |
Control supply voltage 1 at AC | |
at 50 Hz | 110 ... 230 V |
at 60 Hz | 110 ... 230 V |
Control supply voltage frequency | |
1 rated value | 50 Hz |
2 rated value | 60 Hz |
Control supply voltage 1 | |
at DC rated value | 110 V |
Operating range factor control supply voltage rated value at DC | |
initial value | 0.85 |
Full-scale value | 1.1 |
Operating range factor control supply voltage rated value at AC at 50 Hz | |
initial value | 0.85 |
Full-scale value | 1.1 |
Operating range factor control supply voltage rated value at AC at 60 Hz | |
initial value | 1.1 |
Full-scale value | 0.85 |
Control current at AC | |
at 110 V in standby mode | 16 mA |
at 230 V in standby mode | 9 mA |
at 110 V when switching on | 55 mA |
at 230 V when switching on | 33 mA |
at 110 V during operation | 36 mA |
at 230 V during operation | 22 mA |
Control current at DC | |
in standby mode | 6 mA |
when switching on | 15 mA |
during operation | 30 mA |
Response times |
Switch-on delay time | 60 ... 90 ms |
Off-delay time | 60 ... 90 ms |
Installation/ mounting/ dimensions |
Mounting position | vertical, horizontal, standing (observe derating) |
Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail |
Height | 100 mm |
Width | 22.5 mm |
Depth | 141.6 mm |
Required spacing | |
with side-by-side mounting | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 50 mm |
— downwards | 50 mm |
— at the side | 0 mm |
for grounded parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 50 mm |
— at the side | 3.5 mm |
— downwards | 50 mm |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 4 000 m |
Ambient temperature | |
during operation | -25 ... +60 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity during operation | 10 ... 95 % |
Air pressure | |
acc. to SN 31205 | 900 ... 1 060 hPa |
Communication/ Protocol |
Product function Bus communication | No |
Connections/Terminals |
Type of electrical connection | PUSH-IN connection (spring-loaded connection) for main circuit, PUSH-IN connection (spring-loaded connection) for control circuit |
for main current circuit | PUSH-IN connection (spring-loaded connection) |
for auxiliary and control current circuit | PUSH-IN connection (spring-loaded connection) |
Type of connectable conductor cross-sections | |
for main contacts | |
— solid | 1x (0.5 ... 4 mm²) |
— finely stranded with core end processing | 1x (0.5 ... 2.5 mm²) |
— finely stranded without core end processing | 1x (0.5 ... 4 mm²) |
at AWG conductors for main contacts | 1x (20 ... 12) |
Connectable conductor cross-section for main contacts | |
single or multi-stranded | 0.5 ... 4 mm² |
finely stranded with core end processing | 0.5 ... 2.5 mm² |
finely stranded without core end processing | 0.5 ... 4 mm² |
Connectable conductor cross-section for auxiliary contacts | |
single or multi-stranded | 0.5 ... 1.5 mm² |
finely stranded with core end processing | 0.5 ... 1 mm² |
finely stranded without core end processing | 0.5 ... 1.5 mm² |
Type of connectable conductor cross-sections | |
for auxiliary contacts | |
— solid | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) |
— finely stranded with core end processing | 1x (0,5 ... 1,0 mm²), 2x (0,5 ... 1,0 mm²) |
— finely stranded without core end processing | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) |
at AWG conductors for auxiliary contacts | 1x (20 ... 16), 2x (20 ... 16) |
AWG number as coded connectable conductor cross section | |
for main contacts | 20 ... 12 |
for auxiliary contacts | 20 ... 16 |
UL/CSA ratings |
Full-load current (FLA) for three-phase AC motor | |
at 480 V rated value | 6.1 A |
Yielded mechanical performance [hp] | |
for single-phase AC motor | |
— at 110/120 V rated value | 0.25 hp |
— at 230 V rated value | 0.5 hp |
for three-phase AC motor | |
— at 200/208 V rated value | 1 hp |
— at 220/230 V rated value | 1.5 hp |
— at 460/480 V rated value | 3 hp |