Did you mean: PICOSCOPE 2104
Product Datasheet Search Results:
- PICOSCOPE 2104
- Pico Technology
- OSCILLOSCOPE, 10MHZ, 1 CHANNEL, 50MSPS
- PICOSCOPE 2105
- Pico Technology
- OSCILLOSCOPE, 25MHZ, 1 CHANNEL, 100MSPS
- PICOSCOPE 2204A
- Pico Technology
- OSCILLOSCOPE, PC, 2CH, 10MHZ, 100MSPS
- PICOSCOPE 2205A
- Pico Technology
- OSCILLOSCOPE, PC, 2CH, 25MHZ, 200MSPS
- PICOSCOPE 2205 MSO
- Pico Technology
- OSCILLOSCOPE, 18CH, 25MHZ, 200MSPS
- PICOSCOPE 2205 MSO KIT
- Pico Technology
- OSCILLOSCOPE, 18CH, 25MHZ, 200MSPS
- PICOSCOPE 2206A
- Pico Technology
- OSCILLOSCOPE, PC, 2CH, 50MHZ, 500MSPS
- PICOSCOPE 2207A
- Pico Technology
- OSCILLOSCOPE, PC, 2CH, 100MHZ, 1GSPS
- PICOSCOPE 2208A
- Pico Technology
- OSCILLOSCOPE, PC, 2CH, 200MHZ, 1GSPS
- PICOSCOPE 3203D
- Pico Technology
- OSCILLOSCOPE, 2 CHANNEL, 50MHZ, 1GSPS
- PICOSCOPE 3203D MSO
- Pico Technology
- OSCILLOSCOPE, 2+16 CHANNEL, 50MHZ, 1GSPS
Product Details Search Results:
Picotech.com/PICOSCOPE 2104
{"Bandwidth:":"10 MHz","Input Impedance:":"1 Mohm","Sampling Rate:":"50 MSPS","Kit Contents:":"Full SDK Including Example Programs","No. of Channels:":"1","Supply Voltage Min:":"4.6 VDC","Scope Resolution:":"8 bit","Product Range:":"PicoScope 2000 Series","Scope Channels:":"1 Digital","Supply Voltage Max:":"5.25 VDC","Features:":"1 GS/s Repetitive Sampling; Windows 98SE, ME, 2000 & XP Compatible","Display Memory Depth:":"8 kpts","Calculated Rise Time:":"35 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"U...
1435 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2105
{"Bandwidth:":"25 MHz","Input Impedance:":"1 Mohm","Sampling Rate:":"100 MSPS","Kit Contents:":"Full SDK Including Example Programs","No. of Channels:":"1","Supply Voltage Min:":"4.6 VDC","Scope Resolution:":"8 bit","Product Range:":"PicoScope 2000 Series","Scope Channels:":"1 Digital","Supply Voltage Max:":"5.25 VDC","Features:":"2 GS/s Repetitive Sampling; Windows 98SE, ME, 2000 & XP Compatible","Display Memory Depth:":"24 kpts","Calculated Rise Time:":"14 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":...
1438 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2204A
{"Bandwidth:":"10 MHz","Scope Type:":"PC Based","Scope Channels:":"2 Analogue","Kit Contents:":"One 60MHz Passive Probe Per Channel (1:1, 10:1 Switchable), USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2200A Series","Sampling Rate:":"100 MSPS","Input Impedance:":"1 Mohm","Display Memory Depth:":"8 kpts","Calculated Rise Time:":"35 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1316 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2205A
{"Bandwidth:":"25 MHz","Scope Type:":"PC Based","Scope Channels:":"2 Analogue","Kit Contents:":"One 60MHz Passive Probe Per Channel (1:1, 10:1 Switchable), USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2200A Series","Sampling Rate:":"200 MSPS","Input Impedance:":"1 Mohm","Display Memory Depth:":"16 kpts","Calculated Rise Time:":"14 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1284 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2205A-D2
{"Bandwidth:":"25 MHz","Scope Channels:":"2 Analogue","Kit Contents:":"USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2200A Series","Sampling Rate:":"200 MSPS","Display Memory Depth:":"16 kpts","Calculated Rise Time:":"14 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1149 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2205 MSO
{"Bandwidth:":"25 MHz","Scope Type:":"PC Based","Scope Channels:":"2 Analogue, 16 Digital","Kit Contents:":"USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2000 Series","Sampling Rate:":"200 MSPS","Input Impedance:":"1 Mohm","Display Memory Depth:":"48 kpts","Calculated Rise Time:":"14 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"-"}...
1275 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2205 MSO KIT
{"Bandwidth:":"25 MHz","Scope Type:":"PC Based","Scope Channels:":"2 Analogue, 16 Digital","Kit Contents:":"One 60MHz MI007 Passive Probe Per Channel (1:1, 10:1 Switchable), TA136 Digital Cable, 2x TA139 Pack of 10 Test Clips, PicoScope Probe Pouch, USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2000 Series","Sampling Rate:":"200 MSPS","Input Impedance:":"1 Mohm","Display Memory Depth:":"16 kpts","Calculated Rise Time:":"14 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1431 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2206A
{"Bandwidth:":"50 MHz","Scope Type:":"PC Based","Scope Channels:":"2 Analogue","Kit Contents:":"One 60MHz Passive Probe Per Channel (1:1, 10:1 Switchable), USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2200A Series","Sampling Rate:":"500 MSPS","Input Impedance:":"1 Mohm","Display Memory Depth:":"32 kpts","Calculated Rise Time:":"7 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1284 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2207A
{"Bandwidth:":"100 MHz","Scope Type:":"PC Based","Scope Channels:":"2 Analogue","Kit Contents:":"One 150MHz Passive Probe Per Channel (1:1, 10:1 Switchable), USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2200A Series","Sampling Rate:":"1 GSPS","Input Impedance:":"1 Mohm","Display Memory Depth:":"40 kpts","Calculated Rise Time:":"3.5 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1283 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 2208A
{"Bandwidth:":"200 MHz","Scope Channels:":"2 Analogue","Kit Contents:":"One 250MHz Passive Probe Per Channel (1:1, 10:1 Switchable), USB Cable, Software CD, User Manual","Product Range:":"PicoScope 2200A Series","Sampling Rate:":"1 GSPS","Display Memory Depth:":"48 kpts","Calculated Rise Time:":"1.75 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1337 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 3203D
{"Bandwidth:":"50 MHz","Scope Channels:":"2 Analogue","Kit Contents:":"One 60MHz MI007 Passive Probe Per Channel (1:1, 10:1 Switchable), USB Cable, S/W CD, User Manual","Product Range:":"PicoScope 3000 Series","Sampling Rate:":"1 GSPS","Display Memory Depth:":"64 Mpts","Calculated Rise Time:":"7 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1234 Bytes - 18:31:29, 22 November 2024
Picotech.com/PICOSCOPE 3203D MSO
{"Bandwidth:":"50 MHz","Scope Channels:":"2 Analogue, 16 Digital","Kit Contents:":"One 60MHz MI007 Passive Probe Per Channel (1:1, 10:1 Switchable), TA136 Cable, TA139 Clips x2 PK10","Product Range:":"PicoScope 3000 Series","Sampling Rate:":"1 GSPS","Display Memory Depth:":"64 Mpts","Calculated Rise Time:":"7 ns","SVHC:":"No SVHC (15-Jun-2015)","Plug Type:":"USB"}...
1269 Bytes - 18:31:29, 22 November 2024